Standard

BS 8519:2020 - TC

Selection and installation of fire-resistant power and control cable systems for life safety, fire-fighting and other critical applications. Code of practice

Current, Under Review

Published:

What is BS 8519 - Selection and installation of fire-resistant power and control cable systems about? 

BS 8519 specifies buildings that need to develop in terms of increased size height and complexity of active fire protection. 

Who is BS 8519 - Selection and installation of fire-resistant power and control cable systems for?  

BS 8519 on fire-resistant power and control cable systems is relevant to: 

  • Designers 
  • Fire engineers 
  • Regulators and enforcers including building control bodies 
  • Fire authorities 
  • Health and safety inspectors 

Why should you use is BS 8519 - Selection and installation of fire-resistant power and control cable systems?  

Fire-resistant power and control cable systems across applications are vital to ensure safety and protection of property and human life in the event of a fire outbreak. 

BS 8519 is beneficial for structures that need to maintain their circuit integrity during a fire as the function they support is critical for business continuity, property protection, or environmental protection reasons. 

The guidance and recommendations on the selection and installation of fire-resistant power and control cable systems help users maintain circuit integrity for life safety and firefighting. Thus, BS 8519 ensures that the level of circuit fire integrity is not compromised by other components of the whole electrical distribution system, including cable glands, terminations, joints, and cable support systems. 

What’s changed since the last update?  

BS 8519:2020 supersedes BS 8519:2010, which is withdrawn. BS 8519:2020 has been revised and includes the following principal changes: 

  • Added recognition of other critical systems, other than life safety or fire-fighting applications 
  • Added information on uninterruptable power supplies (UPS) 
  • Added life safety and roof-mounted generator recommendations 
  • Added further detailed recommendations included in Clause 12 for the design and selection of the cable enclosure support systems 
  • Clause 12 revised to include the recommendation for internal and external fire stopping to maintain the switch room fire compartmentation and the need to cater for the thermal expansion of the cable protective enclosure
Product Details
Descriptors
Electric cables
Heat
Fire safety in buildings
Fire-resistant materials
Electrical components
Smoke extraction (buildings)
Firefighting
Circuits
Power cables
Fire safety
Fire alarms
Electrical installations
Smoke control
Electric cable systems
Communication cables
Selection
Fire resistance
Electric wiring systems
ICS Codes
13.220.20 Fire protection
29.060.01 Electrical wires and cables in general
Committee
FSH/1
International relationships
ISBN
978 0 539 14407 9
Publisher
BSI