ASTM D3934 - 20 - Standard Test Method for Flash/No Flash Test—Equilibrium Method by a Closed-Cup Apparatus
Essential maintenance work will be carried out on BSI Shop over the weekend of 12 and 13 June 2021. BSI Shop will be operational during this time but you might experience slowness for a very brief period of time. Please accept our apologies for any inconvenience this may cause.

ASTM D3934 - 20

Standard Test Method for Flash/No Flash Test—Equilibrium Method by a Closed-Cup Apparatus

Status : Current   Published : June 2020

Format
PDF

Format
HARDCOPY



1.1 This test method covers the determination of whether a liquid complies with the closed-cup flash point requirements in government regulations, or in specifications, or as agreed between the purchaser and the seller.

1.2 This test method is limited to a temperature range between 0 and 110°C (32 and 230°F).

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4  Warning—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location.

1.5  This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.6  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.




Standard NumberASTM D3934 - 20
TitleStandard Test Method for Flash/No Flash Test—Equilibrium Method by a Closed-Cup Apparatus
StatusCurrent
Publication Date01 June 2020
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors closed cup, flash/no flash, flash point, Pensky-Martens, Tag
ICS87.040
PublisherASTM
FormatA4
DeliveryYes
Pages3
File Size73 KB
Price£37.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Develop a PAS

Develop a fast-track standardization document in 9-12 months


BSOL

Access, view and download standards with multiple user access, across multiple sites with BSOL


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version