ASTM D3161/D3161M - 20 - Standard Test Method for Wind Resistance of Steep Slope Roofing Products (Fan-Induced Method)

ASTM D3161/D3161M - 20

Standard Test Method for Wind Resistance of Steep Slope Roofing Products (Fan-Induced Method)

Status : Current   Published : May 2020

Format
PDF

Format
HARDCOPY



1.1 This test method covers the procedure for evaluating the wind resistance of many discontinuous, air permeable, steep slope roofing products that results from the product's rigidity, with or without contribution from sealant to help hold down the leading edge of the tabs, or mechanical interlocking, with or without contribution from sealant to help hold down the leading edge of the tabs, or any combination thereof. The products are applied to a test panel in accordance with the manufacturer’s instructions and tested at a 2:12 (17 %) slope, or at the lowest slope permitted by those instructions.

1.2 This method evaluates wind resistance using a fan-induced procedure, delivering a stream of air across the exposed surface of the test specimens. This method does not measure structural performance, and does not provide a measure of uplift resistance. Consequently, this method is not applicable to continuous, non-permeable roof systems or coverings (such as membranes or mechanically seamed metal roof panels).

1.3 This test method was formerly titled “Wind Resistance of Asphalt Shingles (Fan-Induced Method)” but was revised to acknowledge that the method is applicable to many other steep slope roofing products and has been used to evaluate the wind resistance of those products for many years by several testing and certification laboratories. Steep slope roofing products that fall under the scope of this test method, in addition to asphalt shingles, are polymer-based shingles, fiber-cement shingles, concrete tiles, clay tiles, metal shingles, and photovoltaic shingles.

1.4 This test method is limited to steep slope roofing product applied with a maximum exposure of 410 mm [16 in.].

1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.

1.6  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.




Standard NumberASTM D3161/D3161M - 20
TitleStandard Test Method for Wind Resistance of Steep Slope Roofing Products (Fan-Induced Method)
StatusCurrent
Publication Date01 May 2020
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors asphalt shingles, clay tiles, concrete tiles, fan-induced winds, fiber-cement shingles, interlockings, metal shingles, photovoltaic shingles, polymer-based shingles, rigidities, roofings, sealants, steep slope roofing products, tabs, wind resistance
ICS91.100.50
PublisherASTM
FormatA4
DeliveryYes
Pages4
File Size73 KB
Price£37.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

Access, view and download standards with multiple user access, across multiple sites with BSOL


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months