BS EN IEC 60079-0:2018 - TC, - Tracked Changes - Tracked Changes. Explosive atmospheres. Equipment. General requirements
We are currently experiencing technical difficulties affecting some customers making purchases using Visa credit or debit card. If you experience any difficulty completing a purchase, please email us on cservices@bsigroup.com.

Find Similar Items

This product falls into the following categories.

You may find similar items within these categories by selecting from the choices below:

BS EN IEC 60079-0:2018 - TC, - Tracked Changes

Tracked Changes. Explosive atmospheres. Equipment. General requirements

Status : Current   Published : March 2019

Format
PDF



IEC 60079-0:2017 is also available as

IEC 60079-0:2017 RLV

which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.



IEC 60079-0:2017 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed that Ex Equipment can be operated are:


-temperature –20 °C to +60 °C;


-pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and


-air with normal oxygen content, typically 21 % v/v.


This part of IEC 60079 and other standards supplementing this standard specify additional test requirements for Ex Equipment operating outside the standard temperature range, but further additional consideration and additional testing may be required for Ex Equipment operating outside the standard atmospheric pressure range and standard oxygen content. Such additional testing may be particularly relevant with respect to Types of Protection that depend on quenching of a flame such as ‘ flameproof enclosures “d”’ (IEC 60079-1) or limitation of energy, ‘intrinsic safety “i”’ (IEC 60079-11). This seventh edition cancels and replaces the sixth edition, published in 2011. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 7.0 and the previous edition of the document.


Keywords: Ex Equipment and Ex Components intended for use in explosive atmospheres


The contents of the interpretation sheet of April 2019 have been included in this copy.




Standard NumberBS EN IEC 60079-0:2018 - TC, - Tracked Changes
TitleTracked Changes. Explosive atmospheres. Equipment. General requirements
StatusCurrent
Publication Date12 March 2019
Cross ReferencesEN 60423:2007, EN ISO 179, EN 20273:1991, EN 60079-35-1:2011/AC:2011, EN ISO 178:2010, EN ISO 4014:2011, EN 60079-1:2014, EN ISO 4027:2003, EN 60947-1:2007, EN 60079-26:2015, EN 60664-1:2007, EN ISO 4017:2011, EN 60529:1991, EN 62626-1:2014, EN ISO 4032:2012, EN 60034-5:2001, EN 60216-2:2005, EN ISO 4892-2:2013, EN ISO 4029:2003, EN 60192:2001, EN 60216-1:2013, EN 60662 (IEC 60662:2011) MOD, EN 60086-1:2015, EN 60529 Corr, EN ISO 527-2:2012, EN ISO 14583:2011, EN ISO 4762:2004, EN 60243-1:2013, EN ISO 7380:2004, EN ISO 4028:2003, EN ISO 4026:2003, EN 60079-20-1:2010, EN 60034-1, EN 60079-31, IEC 17000, EN 60079-7, EN 60079-28, EN 60079-5, EN 60079-13, EN 60079-19, EN 60079-17, EN 61960, EN 61951-1, EN 60079-30-1, EN 60896-21, IEC 80079-36, EN 60079-29-1, EN 61951-2, EN 60079-11, EN 60079-10-2, EN 61427, IEC 80079-20-2, EN 60254, EN 60079-10-1, EN 60079-18, EN 60079-25, EN 60079-29-4, TR 60079-32-1, IEC 80079-34, EN 60079-2, TS 60079-39, TS 60034-25, EN 60079-14, EN 60952, EN 60034-29, EN 60079-15, EN 61056-1, EN 60079-6, EN 60623, EN 60896-11
International RelationshipsIEC 60079-0:2017,EN 62386-209:2011
Draft Superseded By18/30316193 DC
DescriptorsTesting conditions, Fuse-links, Thermal testing, Protected electrical equipment, Earthing, Electric cells, Metals, Marking, Electrical safety, Electrical equipment, Verification, Environmental testing, Switchgear, Electrical testing, Type testing, Plastics, Impact testing, Classification systems, Electric enclosures, Cap lamps, Grades (quality), Fasteners, Mechanical testing, Flammable atmospheres, Drop tests, Test equipment, Type d protected electrical equipment, Rotating electric machines, Explosive atmospheres, Dust, Type i protected electrical equipment, Circuits, Luminaires, Cable glands, Temperature, Electric plugs, Electric sockets
ICS13.230
29.260.20
Title in FrenchAtmosphères explosives Matériel. Exigences générales
Title in GermanExplosionsgefährdete Bereiche Betriebsmittel. Allgemeine Anforderungen
CommitteeEXL/31
ISBN978 0 539 04282 5
PublisherBSI
FormatA4
DeliveryYes
Pages331
File Size6.144 MB
Price£411.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


27 November

Organizational Resilience Annual Conference 2019


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought