ASTM C1103 - 19 - Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines

ASTM C1103 - 19

Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines

Status : Current   Published : January 2019

Format
PDF

Format
HARDCOPY



1.1 This practice covers procedures for testing the joints of installed precast concrete pipe sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint and the construction procedures. This practice is used for testing precast concrete sewer lines utilizing rubber gasket sealed joints.

Note 1:  The user of this practice is advised that methods described herein may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery.

1.2 This practice is the inch-pound companion to Practice C1103M; therefore, no SI equivalents are presented in the practice.

Note 2:  The owner shall specify the following: who will conduct, observe, and furnish labor, material, and measuring devices and pay for the tests; who is responsible for determining local ground conditions; and whether an air or water test is to be used.

Note 3:  The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe shall be accepted by infiltration or exfiltration testing utilizing Practice C969.

Note 4:  Test times tabulated and the rate of air loss in this practice are based on successful testing of installed pipelines. However, since air and water have different physical properties, retests of some pipelines not meeting field air tests have been successful when tested with water.

1.3  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautions are given in Section 6.

1.4  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.




Standard NumberASTM C1103 - 19
TitleStandard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
StatusCurrent
Publication Date01 January 2019
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors Acceptance Criteria And Testing, Force, Pressure, Gaskets, Hydrated Lime, Interlaboratory Studies, Limestone, Physical Process, Physical Test, Precast Concrete Products, Quicklime, Round Robin Test, Settlement, Sewer Pipes, Sieve Analysis
ICS23.040.50
PublisherASTM
FormatA4
DeliveryYes
Pages2
File Size58 KB
Price£36.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months