BS EN IEC 61238-1-2:2019 - Compression and mechanical connectors for power cables. Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (<i>U</i><sub>m</sub> = 1,2 kV) tested on insulated conductors

BS EN IEC 61238-1-2:2019

Compression and mechanical connectors for power cables. Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on insulated conductors

Status : Current   Published : September 2019

Format
PDF

Format
HARDCOPY



This part of EN 61238 applies to insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV), for example according to HD 603 or other buried cables and cables installed in buildings, having a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 300 mm2 for copper and between 16 mm2 and 500 mm2 for aluminium, b) a maximum continuous cable temperature not exceeding the insulation material properties. This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact. The object of this document is to define the type test methods and requirements, which apply to insulation piercing connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused insulated conductors.




Standard NumberBS EN IEC 61238-1-2:2019
TitleCompression and mechanical connectors for power cables. Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on insulated conductors
StatusCurrent
Publication Date30 September 2019
Normative References(Required to achieve compliance to this standard)IEC 60949:1988/AMD1:2008, IEC 60949:1988, IEC 60050-461, IEC 60493-1, EN 60228, IEC 60228
Informative References(Provided for Information)EN 62475:2010, EN 61238-1, IEC 61238-1, IEC 61238-1-3, IEC 61238-1-1, EN IEC 61238-1-1, EN IEC 61238-1-3, IEC 62475:2010
ReplacesBS EN 61238-1:2003
International RelationshipsEN IEC 61238-1-2:2019,IEC 61238-1-2:2018
DescriptorsTemperature, Copper, Short-circuit current tests, Resistance measurement, Electric conductors, Rated voltage, Classification systems, Crimped connectors, Electric wires, Mechanical testing, Thermal-cycling tests, Power cables, Aluminium, Electric cables, Electric connectors, Type testing
ICS29.060.20
29.120.20
Title in FrenchRaccords sertis et à serrage mécanique pour câbles d'énergie Méthodes et exigences d'essai relatives aux raccords sertis et à serrage mécanique pour câbles d'énergie de tensions assignées inférieures ou égales à 1 kV (Um = 1,2 kV) soumis à essai sur des conducteurs non isolés
Title in GermanPressverbinder und Schraubverbinder für Starkstromkabel Prüfverfahren für und Anforderungen an Pressverbinder und Schraubverbinder für Starkstromkabel für Nennspannungen bis zu 1 kV ( Um = 1,2 kV), geprüft an nicht isolierten Leitern
CommitteeGEL/20/11
ISBN978 0 539 02084 7
PublisherBSI
FormatA4
DeliveryYes
Pages62
File Size2.04 MB
Price£254.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Customers who bought this product also bought

  • BS EN IEC 61238-1-1:2019
    Compression and mechanical connectors for power cables Test methods and requirements for compression and mechanical connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on non-insulated conductors
  • BS EN IEC 61238-1-3:2019+A11:2019
    Compression and mechanical connectors for power cables Part 1-3: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV) tested on non-insulated conductors