BS EN IEC 60331-1:2019 - Tests for electric cables under fire conditions. Circuit integrity. Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm

BS EN IEC 60331-1:2019

Tests for electric cables under fire conditions. Circuit integrity. Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm

Status : Current   Published : September 2019

Format
PDF

Format
HARDCOPY



This document EN 60331-1 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. This document is applicable to cables of rated voltage not exceeding 600 V/1?000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables. It is intended for use when testing cables of greater than 20 mm overall diameter. Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used.




Standard NumberBS EN IEC 60331-1:2019
TitleTests for electric cables under fire conditions. Circuit integrity. Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
StatusCurrent
Publication Date05 September 2019
Normative References(Required to achieve compliance to this standard)IEC 60269-3, HD 60269-3, IEC 60584-1, EN 60584-1
Informative References(Provided for Information)No other standards are informatively referenced
ReplacesBS EN 50362:2003
International RelationshipsEN IEC 60331-1:2019,IEC 60331-1:2018
Draft Superseded By16/30342023 DC
DescriptorsFire safety, Emergency electrical installations, Emergency equipment, Fire resistance, Fire tests, Electric cables, Electrical equipment, Circuits
ICS13.220.40
29.060.20
Title in FrenchEssais pour câbles électriques soumis au feu. Intégrité des circuits Méthode d'essai au feu avec chocs pour les câbles de tension assignée au plus égale à 0,6/1,0 kV et de diamètre externe supérieur à 20 mm, à une température d'au moins 830 °C
Title in GermanPrüfungen an Kabeln und isolierten Leitungen im Brandfall. Isolationserhalt Prüfverfahren für Brand mit Erschütterung bei einer Temperatur von mindestens 830 °C für Kabel und isolierte Leitungen mit einer Nennspannung bis einschließlich 0,6/1,0 kV und einem Außendurchmesser größer 20 mm
CommitteeGEL/20/18
ISBN978 0 539 02081 6
PublisherBSI
FormatA4
DeliveryYes
Pages34
File Size1.146 MB
Price£214.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world