ASTM F2544 - 11(2018) - Standard Test Method for Determining A-Weighted Sound Power Level of Central Vacuum Power Units

ASTM F2544 - 11(2018)

Standard Test Method for Determining A-Weighted Sound Power Level of Central Vacuum Power Units

Status : Current   Published : March 2018

Format
PDF

Format
HARDCOPY



1.1 This test method calculates the overall A-weighted sound power level emitted by central vacuum power units, intended for operation in domestic applications. This standard applies to the power unit only at the power unit location. To test the sound power level of a central vacuum at the user’s location, refer to Test Method F1334.

1.2 A-weighted sound pressure measurements are performed on a mounted central vacuum power unit in a semi-reverberant room. This test method determines sound power by a comparison method for small noise sources, that is, comparison to a broad band reference sound source.

1.3 This test method describes a procedure for determining the A-weighted sound power level of small noise sources. This test method uses a non-special semi-reverberant room.

1.4 Results are expressed as A-weighted sound power level in decibels (referenced to 1 pW).

1.5 The values stated in inch pound units are to be regarded as the standard. The values in parentheses are for information only.

1.6  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.




Standard NumberASTM F2544 - 11(2018)
TitleStandard Test Method for Determining A-Weighted Sound Power Level of Central Vacuum Power Units
StatusCurrent
Publication Date01 March 2018
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors A-weighted, central vacuum cleaner, reference sound source (RSS), sound power level, vacuum cleaners
ICS17.140.20
97.080
PublisherASTM
FormatA4
DeliveryYes
Pages9
File Size279 KB
Price£40.00