ASTM D4327 - 17 - Standard Test Method for Anions in Water by Suppressed Ion Chromatography

ASTM D4327 - 17

Standard Test Method for Anions in Water by Suppressed Ion Chromatography

Status : Current   Published : December 2017

Format
PDF

Format
HARDCOPY



1.1 This test method 2,3 covers the sequential determination of fluoride, chloride, nitrite, ortho-phosphate, bromide, nitrate, and sulfate ions in water by suppressed ion chromatography.

Note 1:  Order of elution is dependent upon the column used; see Fig. 1.

1.3 It is the user's responsibility to ensure the validity of this test method for other matrices.

1.4 Concentrations as low as 0.01 mg/L were determined depending upon the anions to be quantified, in single laboratory work. Utilizing a 50-μL sample volume loop and a sensitivity of 3000 μS/cm full scale, the approximate detection limits shown in Table 1 can be achieved. Lower detection limits have been observed with newer instrumentation, column technology and eluents. The analyst must assure optimum instrument performance to maintain a stable baseline at more sensitive conductivity full-scale settings.

(A)  Data provided by U.S. EPA/EMSL Laboratory, Cincinnati, OH.
(B)  Column: as specified in 7.1.4.
  Detector: as specified in 7.1.6.
  Eluent: as specified in 8.3.
  Pump rate: 2.0 mL/min.
  Sample loop: 50 μL.

1.5 The upper limit of this test method is dependent upon total anion concentration and may be determined experimentally as described in Annex A1. These limits may be extended by appropriate dilution or by use of a smaller injection volume.

1.6 Using alternate separator column and eluents may permit additional anions such as acetate, formate, or citrate to be determined. This is not the subject of this test method.

1.7 This test method update approves the use of electrolytically generated eluent, electrolytically regenerated eluent, electrolytic suppression (not autozeroing), and electrolytic trap columns also known as reagent-free ion chromatography. This approval is based on acceptance by the U.S. EPA as referenced in Appendix X2.

1.8 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.9  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.




Standard NumberASTM D4327 - 17
TitleStandard Test Method for Anions in Water by Suppressed Ion Chromatography
StatusCurrent
Publication Date01 December 2017
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors anions, drinking water, ion chromatography, reagent water, wastewater
ICS71.040.40
PublisherASTM
FormatA4
DeliveryYes
Pages13
File Size423 KB
Price£45.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Collaborate, Innovate, Accelerate.


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version