BS EN 62209-2:2010+A1:2019 - Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Human models, instrumentation, and procedures. Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)

BS EN 62209-2:2010+A1:2019

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Human models, instrumentation, and procedures. Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)

Status : Current   Published : August 2010

Format
PDF

Format
HARDCOPY



This part of IEC 62209 series is applicable to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments. For transmitters used in close proximity to the human ear, the procedures of IEC 62209-1:2005 are applicable. This standard is applicable for radio frequency exposure in the frequency range of 30 MHz to 6 GHz, and may be used to measure simultaneous exposures from multiple radio sources used in close proximity to human body. Definitions and evaluation procedures are provided for the following general categories of device types: body-mounted, body-supported, desktop, front-of-face, hand-held, laptop, limb-mounted, multi-band, push-to-talk, clothing-integrated. The types of devices considered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers. This International Standard gives guidelines for a reproducible and conservative measurement methodology for determining the compliance of wireless devices with the SAR limits. Because studies suggest that exclusion of features to represent a hand in human models constitutes a conservative case scenario for SAR in the trunk and the head, a representation of a hand is not included if the device is intended to be used next to the head or supported on or near the torso [73], [80]. This standard does not apply for exposures from transmitting or non-transmitting implanted medical devices. This standard does not apply for exposure from devices at distances greater than 200 mm away from the human body. IEC 62209-2 makes cross-reference to IEC 62209-1:2005 where complete clauses or subclauses apply, along with any changes specified.




Standard NumberBS EN 62209-2:2010+A1:2019
TitleHuman exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Human models, instrumentation, and procedures. Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
StatusCurrent
Publication Date31 August 2010
Normative References(Required to achieve compliance to this standard)EN 62209-1:2006, IEC 17025:2005, IEC 62209-1:2005
Informative References(Provided for Information)IEC Guide 98-3:2008, IEEE Std 1528:2003, IEC 62479, GUM:1995, ISO 10012:2003, IEC Guide 51:1999, IEC 62311:2007
ReplacesBS EN 62209-2:2010
International RelationshipsEN 62209-2:2010/A1:2019,IEC 62209-2:2010/AMD1:2019
Amended ByAmendment, July 2019
Draft Superseded By18/30365325 DC
DescriptorsElectromagnetic radiation, Test dummies, Handheld computers, Radiofrequencies, Mobile communication systems, Test equipment, Human body, Measurement, Radiocommunication, Absorption, Telephone equipment, Measurement characteristics, Electromagnetic fields, Physiological effects (human body), Mobile radio systems, Cordless telephones, Communication equipment, Telephones, Radio-wave hazards
ICS17.220.20
33.050.10
Title in FrenchExposition humaine aux champs radiofréquence produits par les dispositifs de communications sans fils tenus à la main ou portés près du corps. Modèles de corps humain, instrumentation et procédures Procédure de détermination du débit d'absorption spécifique produit par les appareils de communications sans fil utilisés très près du corps humain (gamme de fréquences de 30 MHz à 6 GHz)
Title in GermanSicherheit von Personen in hochfrequenten Feldern von handgehaltenen und am Körper getragenen schnurlosen Kommunikationsgeräten. Körpermodelle, Messgeräte und Verfahren Verfahren zur Bestimmung der spezifischen Absorptionsrate (SAR) von schnurlosen Kommunikationsgeräten, die in enger Nachbarschaft zum menschlichen Körper verwendet werden (Frequenzbereich von 30 MHz bis 6 GHz)
CommitteeGEL/106
ISBN978 0 580 51126 4
PublisherBSI
FormatA4
DeliveryYes
Pages122
File Size3.354 MB
Price£314.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Develop a PAS

Develop a fast-track standardization document in 9-12 months


BSOL

The faster, easier way to work with standards