19/30362629 DC - BS ISO 18310-2. Measurement and prediction of the ambient dose equivalent from patients receiving iodine 131 administration after thyroid ablation. Part 2. After release from the hospital

19/30362629 DC

BS ISO 18310-2. Measurement and prediction of the ambient dose equivalent from patients receiving iodine 131 administration after thyroid ablation. Part 2. After release from the hospital

Status : Current, Draft for public comment   Published : May 2019

Format
PDF

Format
HARDCOPY



This document addresses the measurement methods, procedures and uncertainty estimation for the measurement of the effective dose equivalent to the caregiver in the vicinity of the patient treated with radioiodine to ablate the thyroid using a personal dosimeter.

The general requirements for the patient and caregiver and a guidance (Annex A) for medical practitioners on instructing caregivers of discharged patients is considered to effectively measure the effective dose equivalent to the caregiver in the vicinity of the patient.




Standard Number19/30362629 DC
TitleBS ISO 18310-2. Measurement and prediction of the ambient dose equivalent from patients receiving iodine 131 administration after thyroid ablation. Part 2. After release from the hospital
StatusCurrent, Draft for public comment
Publication Date28 May 2019
Normative References(Required to achieve compliance to this standard)ISO 29661, ISO 4037-3, ISO 4037-1, ISO/IEC Guide 99, ISO 18310-1:2017
Informative References(Provided for Information)No other standards are informatively referenced
International RelationshipsISO/DIS 18310-2
Draft Expiry Date13 July 2019
DescriptorsRadiation protection, Dosimeters, Spectra, Gamma-radiation, Control samples, Exposure-rate meters, Radiation, Photons, Calibration, Radiation measurement, Formulae (mathematics), Homogeneity, Attenuation, Radioactive sources, Radioactive isotopes, Filtration, X-rays, Contamination
ICS13.280
Title in FrenchMesurage et prévision de l'équivalent de dose ambiant de patients bénéficiant d'un traitement par iode 131 après ablation de la thyroïde — Partie 2: Après la sortie de l'hôpital Partie 2: Après la sortie de l'hôpital
CommitteeNCE/2
PublisherBSI
FormatA4
DeliveryYes
Pages20
File Size364 KB
NotesWarning: this draft is not current beyond its expiry date for comments.
Price£20.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version