ASTM F1698 - 02(2015)e1 - Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner Entry Sewers and Conduits

ASTM F1698 - 02(2015)e1

Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner Entry Sewers and Conduits

Status : Current   Published : March 2017

Format
PDF

Format
HARDCOPY



1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits by the installation of a field-fabricated PVC liner. After installation of the liner, cementitious grout is injected into the annular space between the liner and the existing sewer or conduit. The rehabilitation of the host structure by this installation practice results in a rigid composite structure (PVC/grout/existing pipe). This rehabilitation process may be used in a variety of gravity applications, such as sanitary sewers, storm sewers and process piping of man-entry sizes (36 to 144 in. in vertical dimension). The profile strips used for field fabrication of PVC liners are supplied in coils for spiral winding of the liner or in custom-cut flat panels for circumferential lining of all or any portion of the circumference of the host conduit (see Figs. 1 and2).

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.

1.4  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.




Standard NumberASTM F1698 - 02(2015)e1
TitleStandard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner Entry Sewers and Conduits
StatusCurrent
Publication Date01 March 2017
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors Poly(Vinyl Chloride), PVC, Strip Liner, Man-Entry Sewers
ICS23.040.20
PublisherASTM
FormatA4
DeliveryYes
Pages6
File Size271 KB
Price£40.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version