PD IEC/TR 61547-1:2017 - Equipment for general lighting purposes. EMC immunity requirements. An objective light flickermeter and voltage fluctuation immunity test method

PD IEC/TR 61547-1:2017

Equipment for general lighting purposes. EMC immunity requirements. An objective light flickermeter and voltage fluctuation immunity test method

Status : Superseded, Withdrawn   Published : December 2017 Replaced By : PD IEC TR 61547-1:2020

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001


This part of IEC 61547 describes an objective light flickermeter, which can be applied for, amongst others, the following purposes:

  • testing the intrinsic performance of all lighting equipment without voltage fluctuations;

  • testing the immunity performance of lighting equipment against (unintentional) voltage fluctuation disturbance on the AC power port;

  • testing the immunity performance of lighting equipment against intentional voltage fluctuation on the AC power port arising for example from ripple control systems.

The object of this document is to establish a common and objective reference for evaluating the performance of lighting equipment in terms of illuminance flicker. Temporal changes in the colour of light (chromatic flicker) are not considered in this test.

This method can be applied to lighting equipment which is within the scope of IEC technical committee 34, such as lamps and luminaires, intended for connection to a low voltage electricity supply. Independent auxiliaries such as drivers can also be tested by application of a representative light source to that auxiliary.

The objective light flickermeter and voltage fluctuation immunity method described in this document are based on the IEC 61000‑3‑3 standard for voltage fluctuation limits and the flickermeter standard IEC 61000‑4‑15.

The objective light flickermeter described in this document can be applied to objectively assess flicker of lighting equipment that is powered from any type of source, AC mains, DC mains, battery fed or fed through an external dimmer. The specific voltage fluctuation immunity test method described in this document applies to lighting equipment rated for 120 V AC and 230 V AC, 50 Hz and 60 Hz.

NOTE

The principle of the method can be applied for other nominal voltage and frequency ratings.




Standard NumberPD IEC/TR 61547-1:2017
TitleEquipment for general lighting purposes. EMC immunity requirements. An objective light flickermeter and voltage fluctuation immunity test method
StatusSuperseded, Withdrawn
Publication Date31 December 2017
Withdrawn Date09 July 2020
Normative References(Required to achieve compliance to this standard)IEC 61000-3-3:2013, IEC 61000-4-15:2010
Informative References(Provided for Information)IEC TR 61000-1-6:2012, IEC 61547:2009, ISO 11664-1:2007, CIE TN 006:2016, IEC 60050 (all parts), IEC 61547:2009/ISH1:2013
Replaced ByPD IEC TR 61547-1:2020
ReplacesPD IEC/TR 61547-1:2015
International RelationshipsIEC/TR 61547-1:2017
DescriptorsElectric lamps, Electromagnetic compatibility, Surges (electrical), Conformity, Electrical equipment, Interference suppression, Electromagnetic radiation, Grades (quality), Lighting equipment, Electrical testing, Luminaires, Electromagnetic fields, Electrostatics, Lighting systems, Performance, Electric current, Testing conditions
ICS29.140.20
CommitteeCPL/34
ISBN978 0 580 97916 3
PublisherBSI
FormatA4
DeliveryYes
Pages42
File Size2.237 MB
Price£218.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

Access, view and download standards with multiple user access, across multiple sites with BSOL


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months