BS EN IEC 62209-3:2019 - Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz)

BS EN IEC 62209-3:2019

Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz)

Status : Current   Published : November 2019

Format
PDF

Format
HARDCOPY



IEC 62209-3: 2019 specifies measurement protocols and test procedures for the reproducible measurement of peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of a human head or body by radio-frequency (RF) transmitting devices, with a specified measurement uncertainty. Requirements are provided for psSAR assessment using vector measurement-based systems. Such systems determine the psSAR by three-dimensional (3D) field reconstruction within the volume of interest in accordance with the requirements herein for the measurement system, calibration, uncertainty assessment and validation methods. The protocols and procedures apply for the psSAR assessments covering a significant majority of people including children during use of wireless communication devices operated in close proximity to the head or body.


This document is applicable to wireless communication devices intended to be used at a position near the human head or body at distances up to and including 200 mm. This document may be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, combined with other RF-transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range is from 600 MHz to 6 GHz.


The system validation procedures provided within this document cover frequencies from 600 MHz to 6 GHz.


With a vector measurement-based system this document can be employed to evaluate SAR compliance of different types of wireless communication devices.


The wireless communication device categories covered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers, desktop and laptop devices, multi-band, multi-antenna, and push-to-talk devices.


Key Words: Human Exposure, Hand-Held and Body Mounted Wireless Communication Devices.




Standard NumberBS EN IEC 62209-3:2019
TitleMeasurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices. Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz)
StatusCurrent
Publication Date29 November 2019
Normative References(Required to achieve compliance to this standard)ISO/IEC Guide 98-1:2009, EN 62209-2:2010, IEC TR 62630:2010, IEC 62209-2:2010, IEC 62479, EN 62479, GUM:1995, ISO/IEC Guide 98-3, IEC/IEEE 62704-1, IEC 62209-1:2016, EN 62209-1:2016
Informative References(Provided for Information)IEEE 1720:2012, ISO/IEC 17025, NIST TN1297:1994, ISO/IEC 17043, EN ISO/IEC 17043, EN ISO/IEC 17025, EN ISO 3611:2010, ISO 3611:2010
International RelationshipsEN IEC 62209-3:2019,IEC 62209-3:2019
Draft Superseded By18/30355572 DC
DescriptorsElectromagnetic fields, Radio-wave hazards, Mobile communication systems, Telephone equipment, Test dummies, Cordless telephones, Physiological effects (human body), Human body, Handheld computers, Radiofrequencies, Test equipment, Radiocommunication, Measurement, Absorption, Communication equipment, Mobile radio systems, Electromagnetic radiation, Telephones, Measurement characteristics
ICS17.220.20
33.050.10
33.060.20
Title in FrenchProcédure de mesure pour l'évaluation du débit d'absorption spécifique de l'exposition humaine aux champs radiofréquence produits par les dispositifs de communications sans fil tenus à la main ou portes près du corps Systèmes basés sur la mesure vectorielle (plage de fréquences comprise entre 600 MHz et 6 GHz)
Title in GermanMessverfahren für die Beurteilung der spezifischen Absorptionsrate bei der Exposition von Personen gegenüber hochfrequenten Feldern von handgehaltenen und am Körper getragenen schnurlosen Kommunikationsgeräten Auf Vektormessungen basierende Systeme (Frequenzbereich von 600 MHz bis 6 GHz)
CommitteeGEL/106
ISBN978 0 580 97329 1
PublisherBSI
FormatA4
DeliveryYes
Pages144
File Size6.079 MB
Price£328.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months