19/30352974 DC - BS ISO 20043-1. Measurement of radioactivity in the environment. Guidelines for environmental monitoring for effective dose assessment process. Part 1. Planned and existing exposure situation

19/30352974 DC

BS ISO 20043-1. Measurement of radioactivity in the environment. Guidelines for environmental monitoring for effective dose assessment process. Part 1. Planned and existing exposure situation

Status : Current, Draft for public comment   Published : September 2019

Format
PDF

Format
HARDCOPY



International guidelines are intended to protect human health with environmental and food quality by monitoring[2][4][5][6][7][8]. They give a basis for the setting of national regulations and standards for water and food safety in support of public health, including protection against ionizing radiation.

This document provides

  • The way to obtain the data characterizing the different environmental compartments (atmosphere, waters, soils, biological components) and food to assess the human exposure to radionuclides naturally present or discharged by anthropogenic activities,

  • guidance on the environmental characterization needed for the prospective and/or retrospective dose assessment methods of public exposure,

  • guidance to nuclear installations staff in charge of the preparation of radiological assessments in support of permit or authorization applications and National Authorities’ officers in charge of the assessment of public doses for the purposes of determining gaseous or liquid effluent radioactive discharge authorizations,

  • information to the public on the parameters used to conduct a dose assessment of the population living at the vicinity of a nuclear facility. It is important that the dose assessment process be transparent, and that assumptions are clearly understood by stakeholders who can participate in, example, the selection of habits to be taken into account.

Generic mathematical models used for the assessment of radiological human exposure are presented to identify the parameters that shall be monitored in order to select the "best estimates", from the set of measurement results, of these parameter values. More complex models are often used that require the knowledge of supplementary parameters.

The reference and limit values are not included in this document.




Standard Number19/30352974 DC
TitleBS ISO 20043-1. Measurement of radioactivity in the environment. Guidelines for environmental monitoring for effective dose assessment process. Part 1. Planned and existing exposure situation
StatusCurrent, Draft for public comment
Publication Date18 September 2019
Normative References(Required to achieve compliance to this standard)ISO 11074:2015, ISO 80000-10:2009, ISO/IEC Guide 98-3:2008, ISO/IEC Guide 99:2007, ISO/IEC 17025:2005
Informative References(Provided for Information)ISO 13163:2013, ISO 13161:2011, ISO 10473:2000, ISO 11222:2002, ISO 13165-3:2016, ISO 13160:2012, ISO 18589-7:2013, ISO 10704:2009, ISO 18589-6:2009, ISO 9696:2007, ISO 9698:2010, ISO 11665-1:2012, IEC 61577-3:2011, ISO 13165-1:2013, ISO 11665-3:2012, IEC 61577-1:2006, ISO 10381-3, ISO 20899, IEC 1452, ISO 5667-3:2013, ISO 13162:2012, ISO 10381-4, ISO 10381-5, ISO 18589-2:2008, ISO 12749-2, ISO 10381-8, ISO 10381-1, ISO 13169, ISO 18589-3:2008, ISO 11074 (all parts), ISO 11259, ISO 5667-1:2007, ISO/IEC Guide 98-3:2008, ISO 10381-7, ISO 10381-2, ISO 13165-2:2014, ISO 13166:2014, ISO 11665-5:2012, ISO 11665-2:2012, ISO 13168:2015, ISO 13167:2015, ISO 18589-5:2009, ISO 14956:2002, ISO 20042:2019, ISO 13164-3:2013, ISO 13164-4:2015, ISO 11665-7:2012, ISO 18589-1:2005, IEC 61577-4:2009, ISO 18589-4:2009, ISO 11665-4:2012, ISO 11665-6:2012, ISO 17294-2:2016, ISO 11704:2010, IEC 61577-2:2014, ISO 10703:2007, ISO 9697:2008, ISO 20988:2007, ISO 13164-2:2013, ISO 13164-1:2013, ISO 5667-20:2008
International RelationshipsISO/DIS 20043-1
Draft Expiry Date11 November 2019
DescriptorsElectrons, Dosimeters, Radiation, Measurement, Radiation measurement
ICS13.280
17.240
Title in FrenchMesurage de la radioactivité dans l'environnement — Lignes directrices pour lasurveillance environnementale nécessaire à la procédure d'évaluation de la dose efficace — Partie 1: Situation d'exposition existante et planifiée Partie 1: Situation d'exposition existante et planifiée
CommitteeNCE/2
PublisherBSI
FormatA4
DeliveryYes
Pages36
File Size934 KB
NotesWarning: this draft is not current beyond its expiry date for comments.
Price£20.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Collaborate, Innovate, Accelerate.


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


BSOL

The faster, easier way to work with standards