BS EN 61000-4-16:2016 - Electromagnetic compatibility (EMC). Testing and measurement techniques. Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz

BS EN 61000-4-16:2016

Electromagnetic compatibility (EMC). Testing and measurement techniques. Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz

Status : Current   Published : March 2016

Format
PDF

Format
HARDCOPY



This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz.

The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports.

This standard defines

  • test voltage and current waveform;

  • range of test levels;

  • test equipment;

  • test set-up;

  • test procedures.

For some types of ports, for example ports intended to be used with highly balanced lines, additional test provisions may be established by product committee specifications.

The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted, common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system.

The disturbances produced by 400 Hz mains systems are not included in the scope of this standard.

Actual interference due to these disturbance phenomena is relatively rare, except in industrial plants. Product committees should therefore consider whether there is a justification for applying this standard in their product/product family standards (see also Clause 4).

This test is not relevant for equipment ports intended to be connected to short cables, having a length less than 20 m or less.

The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports (in differential mode) is not included in the scope of this standard and is covered by IEC 61000‑4‑13 and IEC 61000‑4‑19.

The immunity to conducted disturbances generated by intentional radio-frequency transmitters is not included in the scope of this standard and is covered by IEC 61000‑4‑6.




Standard NumberBS EN 61000-4-16:2016
TitleElectromagnetic compatibility (EMC). Testing and measurement techniques. Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
StatusCurrent
Publication Date31 March 2016
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)IEC 61000-4-6, EN 61000-4-6, IEC 61000-4-13, EN 61000-4-13, IEC 61000-4-19, EN 61000-4-19, IEC 60068-1, EN 60068-1, IEC 61000-4, EN 61000-4, IEC 60381-2, IEC 61000-2-3, IEC TR 61000-2-5, IEC 60050-161
ReplacesBS EN 61000-4-16:1998+A2:2011
International RelationshipsEN 61000-4-16:2016,IEC 61000-4-16:2015
Amended ByCorrigendum, August 2016.
Draft Superseded By14/30310431 DC
DescriptorsElectromagnetic compatibility, Electromagnetic radiation, Electromagnetic fields, Electric power system disturbances, Electrical measurement, Electromagnetism, Test equipment, Testing conditions, Environmental testing, Environment (working), Electrical equipment, Electronic equipment and components, Electrostatics, Magnetic fields, Voltage fluctuations, Laboratory testing, Performance testing
ICS33.100.20
Title in FrenchCompatibilité électromagnétique (CEM). Techniques d'essai et de mesure. Essai d'immunité aux perturbations conduites en mode commun dans la plage de fréquences de 0 Hz à 150 kHz
Title in GermanElektromagnetische Verträglichkeit (EMV). Prüf- und Messverfahren. Prüfung der Störfestigkeit gegen leitungsgeführte, asymmetrische Störgrößen im Frequenzbereich von 0 Hz bis 150 kHz
CommitteeGEL/210/11
ISBN978 0 580 95564 8
PublisherBSI
FormatA4
DeliveryYes
Pages32
File Size2.137 MB
Price£182.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought

  • BS EN 61000-4-8:2010
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Power frequency magnetic field immunity test
  • BS EN 61000-4-9:2016
    Electromagnetic compatibility (EMC) Testing and measurement techniques. Impulse magnetic field immunity test