ASTM E1836/E1836M - 09(2016) - Standard Practice for Building Floor Area Measurements for Facility Management

ASTM E1836/E1836M - 09(2016)

Standard Practice for Building Floor Area Measurements for Facility Management

Status : Current   Published : March 2016

Format
PDF

Format
HARDCOPY



1.1 This practice provides a definitive procedure for measuring and classifying floor area in buildings for use in facility management, specifying occupant requirements, space planning, and for strategic facility planning.

1.2 This practice specifies the sequence in which to measure floor area.

1.3 This practice is applicable to owned, rented, and leased buildings.

1.4 Use Annex A1 to measure floor area in office facilities. The measurement practice in Annex A1 may also be suitable for use in other functional types of building which include offices, such as research, laboratory, or manufacturing buildings and building-related facilities.

1.5 The practice in Annex A1 is not intended for use in lease negotiations with owners of commercial office buildings or related properties. For that purpose, refer to the American National Standard published by the American National Standards Institute under the designation ANSI/BOMA Z65.1–1996 and commonly known as the ANSI-BOMA standard.

1.6 This practice is not intended for and not suitable for use for regulatory purposes, fire hazard assessment, and fire risk assessment.

1.7 This practice was developed for use within North America and includes some rules comparable to ISO 9836 Performance Standards in Building—Definition and Calculation of Area and Space Indicators.

1.8 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.




Standard NumberASTM E1836/E1836M - 09(2016)
TitleStandard Practice for Building Floor Area Measurements for Facility Management
StatusCurrent
Publication Date01 March 2016
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors area, building, building floor area, facility, facility management, floor area, measurement, occupant requirement
ICS17.040.01
35.240.67
91.140.01
PublisherASTM
FormatA4
DeliveryYes
Pages17
File Size1.593 MB
Price£45.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months