BS EN IEC 63009:2019

Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 20 kHz to 500 kHz

Status : Current   Published : September 2019

Format
PDF

Format
HARDCOPY



IEC 63009:2019 is applicable to ultrasonic equipment designed for physiotherapy containing an ultrasonic transducer generating ultrasound in the frequency range 20 kHz to 500 kHz.


This document only relates to ultrasonic physiotherapy equipment employing a single plane non-focusing circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head.


This document specifies:


• methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods;


• characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment;


• methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods;


• acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment.


The therapeutic value and methods of use of ultrasonic physiotherapy equipment are not within the scope of this document.


Excluded equipment includes, but is not limited to:


• equipment in which ultrasound waves are intended to destroy conglomerates (for example stones in the kidneys or the bladder) or tissue of any type;


• equipment in which a tool is driven by ultrasound (for example surgical scalpels, phacoemulsifiers, dental scalers or intracorporeal lithotripters);


• equipment in which ultrasound waves are intended to sensitize tissue to further therapies (for example radiation or chemotherapy);


• equipment in which ultrasound waves are intended to treat cancerous (i.e., malignant) or pre-cancerous tissue, or benign masses, such as High Intensity Focused Ultrasound (HIFU) or High Intensity Therapeutic Ultrasound (HITU).




Standard NumberBS EN IEC 63009:2019
TitleUltrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 20 kHz to 500 kHz
StatusCurrent
Publication Date23 September 2019
Cross ReferencesEN 60565, IEC 62127-2, IEC 60601-2-5, IEC 62127-1, EN 62127-1, EN 60601-2-5, EN 62127-2, IEC 60565, EN 62555, EN 62127-3, IEC TR 62781, IEC 61161, IEC TR 60854, IEC 60050-801, EN 61161, IEC 60601-1, IEC 62127-3, IEC 60050-802, IEC 62555, IEC TS 62556, EN 61689:2013, IEC 61689:2013
International RelationshipsEN IEC 63009:2019,IEC 63009:2019
Draft Superseded By18/30344473 DC
DescriptorsTransducers, Specifications, Measurement, Physiotherapy, Ultrasonics
ICS11.040.60
17.140.50
Title in FrenchUltrasons. Systèmes de physiothérapie. Spécifications des champs et méthodes de mesure dans la plage de fréquences de 20 kHz à 500 kHz
Title in GermanUltraschall. Physiotherapiesysteme. Feldspezifikationen und Messmethoden im Frequenzbereich 20 kHz bis 0,5 MHz
CommitteeEPL/87
ISBN978 0 580 94831 2
PublisherBSI
FormatA4
DeliveryYes
Pages42
File Size1.226 MB
Price£206.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Collaborate, Innovate, Accelerate.


Worldwide Standards
We can source any standard from anywhere in the world