ASTM F773M - 16 - Standard Practice for Measuring Dose Rate Response of Linear Integrated Circuits (Metric)

ASTM F773M - 16

Standard Practice for Measuring Dose Rate Response of Linear Integrated Circuits (Metric)

Status : Current   Published : May 2016

Format
PDF

Format
HARDCOPY



1.1 This practice covers the measurement of the response of linear integrated circuits, under given operating conditions, to pulsed ionizing radiation. The response may be either transient or more lasting, such as latchup. The radiation source is either a flash X-ray machine (FXR) or an electron linear accelerator (LINAC).

1.2 The precision of the measurement depends on the homogeneity of the radiation field and on the precision of the radiation dosimetry and the recording instrumentation.

1.3 The test may be considered to be destructive either for further tests or for other purposes if the total radiation ionizing dose exceeds some predetermined level or if the part should latch up. Because this level depends both on the kind of integrated circuit and on the application, a specific value must be agreed upon by the parties to the test. (See 6.10.)

1.4 Setup, calibration, and test circuit evaluation procedures are included in this practice.

1.5 Procedures for lot qualification and sampling are not included in this practice.

1.6 Because response varies with different device types, the dose rate range and device upset conditions for any specific test is not given in this practice but must be agreed upon by the parties to the test.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.




Standard NumberASTM F773M - 16
TitleStandard Practice for Measuring Dose Rate Response of Linear Integrated Circuits (Metric)
StatusCurrent
Publication Date01 May 2016
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors Circuit response, Dose rate, Integrated circuit, Ionizing radiation, Linear circuits, Linear integrated circuits, Pulsed radiation, Transient response
ICS31.020
PublisherASTM
FormatA4
DeliveryYes
Pages6
File Size136 KB
Price£40.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


BSOL

The faster, easier way to work with standards