ASTM C1715/C1715M - 15 - Standard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems

ASTM C1715/C1715M - 15

Standard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems

Status : Current   Published : July 2015

Format
PDF

Format
HARDCOPY



1.1 This test method describes a standard procedure for determining the ability of masonry wall drainage systems to collect water that penetrates the exterior masonry wythe during rainstorms and to direct this water back to the exterior surface of the wall.

1.2 This test method is applicable to wall systems that contain an exterior masonry wythe with a drainage zone on the interior face of the exterior wythe. It is not applicable to single-wythe drainage walls.

1.3 This test method is not applicable to masonry barrier walls or other masonry walls that are designed without drainage zones behind the exterior wythe.

1.4 This test method covers the application of the testing using either inch-pound or SI units. The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.

1.5  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.




Standard NumberASTM C1715/C1715M - 15
TitleStandard Test Method for Evaluation of Water Leakage Performance of Masonry Wall Drainage Systems
StatusCurrent
Publication Date01 July 2015
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors Drainage zone, Flashing, Masonry, Masonry drainage walls, Water leakage, Weep system
ICS91.080.30
PublisherASTM
FormatA4
DeliveryYes
Pages9
File Size671 KB
Price£40.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Worldwide Standards
We can source any standard from anywhere in the world