This document describes the methods for determining the activity in becquerel (Bq) of gamma?ray emitting radionuclides in test samples by gamma-ray spectrometry. The measurements are carried out in a testing laboratory following proper sample preparation. The test samples can be solid, liquid or gaseous. Applications include:

  • routine surveillance of radioactivity released from nuclear installations or from sites discharging enhanced levels of naturally occurring radioactive materials;

  • contributing to determining the evolution of radioactivity in the environment;

  • investigating accident and incident situations, in order to plan remedial actions and monitor their effectiveness;

  • assessment of potentially contaminated waste materials from nuclear decommissioning activities;

  • surveillance of radioactive contamination in media such as soils, foodstuffs, potable water, groundwaters, seawater or sewage sludge;

  • measurements for estimating the intake (inhalation, ingestion or injection) of activity of gamma-ray emitting radionuclides in the body.

It is assumed that the user of this document has been given information on the composition of the test sample or the site. In some cases, the radionuclides for analysis have also been specified if characteristic limits are needed. It is also assumed that the test sample has been homogenised and is representative of the material under test.

General guidance is included for preparing the samples for measurement. However, some types of sample are to be prepared following the requirements of specific standards referred to in this document. The generic recommendations can also be useful for the measurement of gamma-ray emitters in situ.

This document includes generic advice on equipment selection (see Annex A), detectors (more detailed information is included in Annex D), and commissioning of instrumentation and method validation. Annex F summarises the influence of different measurement parameters on results for a typical gamma-ray spectrometry system. Quality control and routine maintenance are also covered, but electrical testing of the detector and pulse processing electronics is excluded. It is assumed that any data collection and analysis software used has been written and tested in accordance with relevant software standards such as ISO/IEC/IEEE 12207.

Calibration using reference sources and/or numerical methods is covered, including verification of the results. It also covers the procedure to estimate the activity content of the sample (Bq) from the spectrum.

The principles set out in this document are applicable to measurements by gamma-ray spectrometry in testing laboratories and in situ. However, the detailed requirements for in situ measurement are given in ISO 18589-7 and are outside the scope of this document.

This document covers, but is not restricted to, gamma-ray emitters which emit photons in the energy range of 5 keV to 3 000 keV. However, most of the measurements fall into the range 40 keV to 2 000 keV. The activity (Bq) ranges from the low levels (sub-Bq) found in environmental samples to activities found in accident conditions and high level radioactive wastes.




Standard NumberBS ISO 20042:2019
TitleMeasurement of radioactivity. Gamma-ray emitting radionuclides. Generic test method using gamma-ray spectrometry
StatusCurrent
Publication Date10 June 2019
Normative References(Required to achieve compliance to this standard)ISO/IEC Guide 98-3:2008, ISO 5500, ISO 18400-107, ISO 5667-10, ISO 18400-104, ISO 18400-204, ISO 5667-1, ISO 17604, ISO 18400-103, ISO 18400-101, ISO/IEC 17025, ISO 11929, ISO 18589-2, ISO 542, ISO 5538, ISO 18400-102, GUM:1995, ISO 707, ISO 18400-203, ISO 24333, ISO 18400-205, ISO 10703, ISO 18589-7, ISO 18400-202
Informative References(Provided for Information)ISO 18589-3, ANSI N42.14-1999, ISO/IEC/IEEE 12207, IEC 1452:1995, IEC 61453, ISO 19581, ISO 7870-2:2013, ISO 13164-2:2013, ISO 13779-6:2015, ISO 19361:2017, ISO 1998-4:1998 (R04), ISO 13165-3:2016
International RelationshipsISO 20042:2019
Draft Superseded By18/30327040 DC
DescriptorsQuality assurance, Radiation measurement, Health and safety requirements, Statistical methods of analysis, Confidentiality, Dosimeters, Nuclear safety, Cytology, Safety measures, Estimation, Biological analysis and testing, Quality control, Radiation protection, Performance testing, Calibration, Laboratory accreditation, Test laboratories, Laboratories, Error correction, Data security
ICS13.280
Title in FrenchMesurage de la radioactivité. Radionucléides émetteurs de rayons gamma. Méthode dessai générique par spectrométrie à rayons gamma
CommitteeNCE/2
ISBN978 0 580 90978 8
PublisherBSI
FormatA4
DeliveryYes
Pages60
File Size2.26 MB
Price£254.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


BSOL

The faster, easier way to work with standards


Worldwide Standards
We can source any standard from anywhere in the world