ASTM E816 - 15 - Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
Maintenance will be taking place for Shop on Friday 21st February between 17:00 and 23:00 UK time. Shop will be unavailable during this time or will have limited functionality. Please accept our apologies for any inconvenience caused during this essential maintenance.

Related Standards

ASTM E816 - 15

Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers

Status : Current   Published : January 2015

Format
PDF

Format
HARDCOPY



1.1 This test method has been harmonized with, and is technically equivalent to, ISO 9059.

1.2 Two types of calibrations are covered by this test method. One is the calibration of a secondary reference pyrheliometer using an absolute cavity pyrheliometer as the primary standard pyrheliometer, and the other is the transfer of calibration from a secondary reference to one or more field pyrheliometers. This test method prescribes the calibration procedures and the calibration hierarchy, or traceability, for transfer of the calibrations.

Note 1:  It is not uncommon, and is indeed desirable, for both the reference and field pyrheliometers to be of the same manufacturer and model designation.

1.3 This test method is relevant primarily for the calibration of reference pyrheliometers with field angles of 5 to 6°, using as the primary reference instrument a self-calibrating absolute cavity pyrheliometer having field angles of about 5°. Pyrheliometers with field angles greater than 6.5° shall not be designated as reference pyrheliometers.

1.4 When this test method is used to transfer calibration to field pyrheliometers having field angles both less than 5° or greater than 6.5°, it will be necessary to employ the procedure defined by Angstrom and Rodhe. 2

1.5 This test method requires that the spectral response of the absolute cavity chosen as the primary standard pyrheliometer be nonselective over the range from 0.3 to 10 μm wavelength. Both reference and field pyrheliometers covered by this test method shall be nonselective over a range from 0.3 to 4 μm wavelength.

1.6 The primary and secondary reference pyrheliometers shall not be field instruments and their exposure to sunlight shall be limited to calibration or intercomparisons. These reference instruments shall be stored in an isolated cabinet or room equipped with standard laboratory temperature and humidity control.

Note 2:  At a laboratory where calibrations are performed regularly, it is advisable to maintain a group of two or three secondary reference pyrheliometers that are included in every calibration. These serve as controls to detect any instability or irregularity in the standard reference pyrheliometer.

1.7 This test method is applicable to calibration procedures using natural sunshine only.




Standard NumberASTM E816 - 15
TitleStandard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
StatusCurrent
Publication Date02 January 2015
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Descriptors Calibration Pyrheliometers Solar Energy
ICS27.160
PublisherASTM
FormatA4
DeliveryYes
Pages11
File Size279 KB
Price£45.00