IEC 61238-1-3:2018 - Compression and mechanical connectors for power cables. Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) tested on non-insulated conductors

IEC 61238-1-3:2018

Compression and mechanical connectors for power cables. Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) tested on non-insulated conductors

Status : Current   Published : May 2018

Format
PDF

Format
HARDCOPY



IEC 61238-1-3:2018 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (

Um

= 1,2 kV) up to 30 kV (

Um

= 36 kV), for example buried cables or cables installed in buildings, having


a) conductors complying with IEC 60228 having nominal cross-sectional areas between 2,5 mm

2

and 1 200 mm

2

for copper and between 16 mm

2

and 1 200 mm

2

for aluminium, excluding Milliken conductors;


b) a maximum continuous conductor temperature not exceeding 90 °C.


This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.


The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.


This first edition, together with IEC 61238-1-1 and IEC 61238-1-2, cancels and replaces IEC 61238-1:2003.


This edition includes the following significant technical changes with respect to IEC 61238­-1:2003:


a) The scope has been widened to cover connectors for conductors from 10 mm

2

down to 2,5 mm

2

and has been limited to 1 200 mm

2

for connectors for copper and aluminium conductors because test experience and applications are rare for conductors of larger cross-sectional areas.


b) A new mechanical class has been introduced to satisfy the demand for connectors subjected to higher mechanical forces than those specified in Class 1 for conductors of larger cross-sectional areas.


c) For the electrical test, a maximum elevated heating current has been set in order to avoid unrealistic current densities during the test which may change the properties of tested connectors.


d) For the short-circuit test, the method of calculation and requirements have been updated.


e) For the mechanical test, the methods and requirements have been updated.


f) A proposal for an electrical test on cable terminal lugs for application in separable connectors has been introduced.




Standard NumberIEC 61238-1-3:2018
TitleCompression and mechanical connectors for power cables. Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) tested on non-insulated conductors
StatusCurrent
Publication Date08 May 2018
Normative References(Required to achieve compliance to this standard)IEC 60949:1988, IEC 60949:1988/AMD1:2008, IEC 60050-461, IEC 60228, IEC 60493-1
Informative References(Provided for Information)BS 4579-3:1976, IEC 62475:2010, IEC 61238-1-2, IEC 61238-1-1, IEC 61238-1
Draft Superseded ByIEC 61238-1-3 ED.1.0
ICS29.060.20
Title in FrenchIEC 61238-1-3 ED1: Raccords sertis et à serrage mécanique pour câbles d’énergie - Partie 1-3:
CommitteeGEL/20/11
ISBN978-2-8322-5647-3
PublisherIEC
FormatA4
DeliveryYes
Pages94
File Size1.952 MB
Price£196.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Collaborate, Innovate, Accelerate.


BSOL

The faster, easier way to work with standards


Worldwide Standards
We can source any standard from anywhere in the world


Customers who bought this product also bought

  • IEC 61238-1-2:2018
    Compression and mechanical connectors for power cables Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on insulated conductors