BS EN 50130-4:2011+A1:2014 - Alarm systems. Electromagnetic compatibility. Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems

BS EN 50130-4:2011+A1:2014

Alarm systems. Electromagnetic compatibility. Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems

Status : Current   Published : August 2011

Format
PDF

Format
HARDCOPY



This EMC product-family standard, for immunity requirements, applies to the components of the following alarm systems, intended for use in and around buildings in residential, commercial, light industrial and industrial environments:

  • access control systems, for security applications;

  • alarm transmission systems 1);

  • CCTV systems, for security applications;

  • fire detection and fire alarm systems;

  • hold-up alarm systems;

  • intruder alarm systems;

  • social alarm systems;

The tests and severities to be used are the same for indoor and outdoor applications of fixed, movable and portable equipment.

The levels do not cover extreme cases, which may occur in any location, but with an extremely low probability of occurrence, or in special locations close to powerful emitters (e.g. radar transmitters).

Equipment within the scope of this standard should be designed in order to operate satisfactorily in the environmental electromagnetic conditions of residential, commercial, light industrial and industrial environments. This implies particularly that it should be able to operate correctly within the conditions fixed by the electromagnetic compatibility levels for the various disturbances on the low voltage public supply system as defined by EN 61000‑2‑2. The immunity tests in this standard only concern the most critical disturbance phenomena.

For equipment using radio signalling, mains signalling or with connections to the public telephone system, additional requirements, from other standards specific to these signalling media, might apply.

This standard does not specify basic safety requirements, such as protection against electrical shocks, unsafe operation, insulation coordination and related dielectric tests.

This standard does not cover EMC emission requirements. These are covered by other appropriate standards.




Standard NumberBS EN 50130-4:2011+A1:2014
TitleAlarm systems. Electromagnetic compatibility. Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
StatusCurrent
Publication Date31 August 2011
Normative References(Required to achieve compliance to this standard)IEC 60068-1:1988, IEC 61000-4-3:2006/AMD 2:2010, EN 61000-4-5:2006, IEC 61000-4-3:2006/AMD 1:2007, IEC 61000-4-5:2005, EN 61000-4-3:2006/AMD 1:2008, ETSI EN 301 489, IEC 61000-4-6:2008, IEC 61000-4-11:2004, EN 61000-4-3:2006, IEC 61000-4-2:2008, IEC 60068-1:1988/Corrigendum:1988, EN 61000-4-3:2006/AMD 2:2010, IEC 61000-4-4:2004/AMD 1:2010, EN 61000-4-20:2010, IEC 60068-1:1988/AMD 1:1992, EN 60068-1:1994, EN 61000-4-11:2004, IEC 61000-4-4:2004, IEC 61000-4-20:2010, EN 61000-4-4:2004/AMD 1:2010, EN 61000-4-4:2004, EN 61000-4-2:2009, IEC 61000-4-3:2006, EN 61000-4-6:2009
Informative References(Provided for Information)EN 50132, EN 50133, EN 50134, EN 54, 2004/108/EC, EN 50136, CLC/TS 50398, EN 61000-2-2:2002, EN 61000-4-16, IEC 61000-2-2:2002, EN 50131, IEC 61000-4-16
ReplacesBS EN 50130-4:1996
International RelationshipsEN 50130-4:2011/A1:2014
Amended ByAmendment, November 2014
DescriptorsElectrical testing, Burglar alarms, Electromagnetic fields, Testing conditions, Interruption tests, Special-purpose alarms, Alarm systems, Safety measures, Electric discharges, Closed-circuit television, Warning devices, Electrostatics, Circuits, Electric power system disturbances, Electromagnetism, Fire alarms, Electromagnetic radiation, Electromagnetic compatibility, Impulse-voltage tests
ICS13.220.20
13.310
13.320
33.100.20
Title in FrenchSystèmes d'alarme. Compatibilité électromagnétique. Norme de famille de produits. Exigences relatives à l'immunité des composants des systèmes d 'alarme de détection d'incendie, contre l'intrusion, contre les hold-up, CCTV, de contrôle d'accès et d'alarme sociale
Title in GermanAlarmanlagen. Elektromagnetische Verträglichkeit. Produktfamiliennorm. Anforderungen an die Störfestigkeit von Anlageteilen für Brandmeldeanlagen, Einbruch- und Überfallmeldeanlagen, VideoÜberwachungsanlagen, Zutrittskontrollanlagen sowie Personen-Hilferufanlagen
CommitteeGW/1
ISBN978 0 580 82744 0
PublisherBSI
FormatA4
DeliveryYes
Pages30
File Size1.497 MB
Price£182.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Customers who bought this product also bought