BS EN 54-22:2015 - Fire detection and fire alarm systems. Resettable line-type heat detectors

BS EN 54-22:2015

Fire detection and fire alarm systems. Resettable line-type heat detectors

Status : Current, Work in hand   Published : May 2015

Format
PDF

Format
HARDCOPY



This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011). This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of resettable line-type heat detectors to this EN. This European Standard also covers resettable line-type heat detectors intended for use in the local protection of plant and equipment. Resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this EN. This European Standard does not cover line-type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called digital systems).




Standard NumberBS EN 54-22:2015
TitleFire detection and fire alarm systems. Resettable line-type heat detectors
StatusCurrent, Work in hand
Publication Date31 May 2015
Normative References(Required to achieve compliance to this standard)IEC 60068-2-42:2003, EN 60068-1:1994, EN 60068-2-2:2007, IEC 60068-2-30:2005, IEC 60068-2-78:2001, EN 60068-2-42:2003, EN 60068-2-6:2008, EN 60068-2-30:2005, EN 60068-2-1:2007, EN 60068-2-78:2001, IEC 60068-1:1988+Corrigendum:1988+A1:1992, IEC 60068-2-2:2007, IEC 60068-2-27:2009, EN 60068-2-27:2009, IEC 60068-2-6:2008, IEC 60068-2-1:2007, EN 60068-2-75:1997, EN 54-1:2011, IEC 60068-2-75:1997, EN 50130-4:2011, EN 54-7:2000
Informative References(Provided for Information)ISO 9001:2008, EN ISO 9001:2008, EN 54-2:1997
International RelationshipsEN 54-22:2015
DescriptorsConformity, Fire alarms, Alarm systems, Fire safety, Automatic, Warning devices, Fire safety in buildings, Fire detectors, Automatic control systems
ICS13.220.10
13.220.20
Title in FrenchSystèmes de détection et d'alarme incendie. Détecteurs de chaleur de type linéaire réenclenchables
Title in GermanBrandmeldeanlagen. Rücksetzbare linienförmige Wärmemelder
CommitteeFSH/12/2
ISBN978 0 580 81246 0
PublisherBSI
FormatA4
DeliveryYes
Pages88
File Size929 KB
Price£274.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version