BS IEC 61017:2016 - Radiation protection instrumentation. Transportable, mobile or installed equipment to measure photon radiation for environmental monitoring

BS IEC 61017:2016

Radiation protection instrumentation. Transportable, mobile or installed equipment to measure photon radiation for environmental monitoring

Status : Current   Published : March 2016

Format
PDF

Format
HARDCOPY



This International Standard is applicable to transportable, mobile or installed assemblies intended to measure environmental air kerma rates or air absorbed dose rates from 30 nGy⋅h –1 to 30 µGy⋅h –1 or ambient dose equivalent rates from 30 nSv⋅h –1 to 30 µSv⋅h –1, or air kerma or air absorbed dose from 10 nGy to 10 mGy, or ambient dose equivalent from 10 nSv to 10 mSv, due to photon radiation of energy between 50 keV and 7 MeV. The measurable range of dose and dose rate can be extended by agreement between the purchaser and the manufacturer. This extension may be realized by combining more than one detector, for example NaI(Tl) scintillator and ionization chamber. For most environmental applications, instruments may measure over a more limited energy range of 80 keV to 3 MeV.

NOTE 1

80 keV to 3 MeV has been chosen to cover the energies of the chief environmental and man-made radio-nuclides that contribute to the environmental dose. The term “dose” used in this standard means the quantity, air kerma, air absorbed dose, and ambient dose equivalent, that the instrument is intended to measure.

If the assembly is to be used to measure these quantities in the area surrounding a nuclear reactor producing 6 MeV radiation from the 16N isotope, it will be necessary to determine the response at this energy. An absorbed dose in air, which uses the same unit, Gy, as air kerma can be taken to have the same numerical value as air kerma under the condition of electron equilibrium.

Passive devices such as Thermo-Luminescence Dosemeter (TLD), Optically Stimulated Luminescence (OSL) Dosemeter or Glass Radio-Photo Luminescence (RPL) Dosemeter are not covered by this standard.

Installed assemblies should be capable of operating continuously.

This standard does not provide for the measurement of beta and neutron radiation.

The equipment covered by this standard comprises a detector assembly and processing circuits, which may be connected together either rigidly or by means of a flexible cable, or incorporated into a single assembly. The equipment assembly may also include circuits for displaying readings, alarms and communication.

This equipment should meet the environmental conditions of use.

Examples of instruments include (detailed information is described in Annex A):

  1. Ionization chamber

    This is suitable for the measurement of air kerma and air absorbed dose and dose rate. In the environment, the correction due to temperature and atmospheric pressure may be required.

    NOTE 2

    For the measurement of ambient dose equivalent and dose equivalent rate the energy response may be compensated.

  2. Geiger-Muller (GM) counter

    The energy response should be corrected. GM counters may overestimate the readings due to the dose (rate) from cosmic radiation.

  3. Scintillation detector

    The energy response should be corrected. Detailed information is described in Annex A and Annex B.

  4. Semiconductor detector

    The energy response should be corrected.




Standard NumberBS IEC 61017:2016
TitleRadiation protection instrumentation. Transportable, mobile or installed equipment to measure photon radiation for environmental monitoring
StatusCurrent
Publication Date31 March 2016
Normative References(Required to achieve compliance to this standard)ISO 4037-1:1996, IEC 60050-395:2014, ISO 4037-4:2004, IEC 60529, IEC 61000-4-12, ISO 4037-2:1997, IEC 61000-4-5, IEC 61000-4-8, IEC 61187, IEC 61000-4-11, IEC 61000-6-2, IEC 61000-4-6, IEC 61000-4-3, IEC 60038, IEC 60086-1, ISO 4037-3:1999, IEC 60068-2-75, IEC 61000-4-4, IEC 62262, IEC 61000-4-2
Informative References(Provided for Information)No other standards are informatively referenced
International RelationshipsIEC 61017:2016
Draft Superseded By14/30269872 DC
DescriptorsGamma-radiation, Error analysis, Certificates of conformity, Type testing, Environmental health, Fixed, Contamination meters, Radiation measurement, Radiation protection, Nuclear safety, Errors, Nuclear technology, Monitors, Calibration, Definitions, Environmental testing, Portable, Radiation hazards, Testing conditions, Ionization counters, Transportable, Electrical testing, X-rays
ICS13.280
Title in FrenchInstrumentation pour la radioprotection. Equipement transportable, mobile ou installé pour mesurer le rayonnement de photons pour la surveillance de l'environnement
CommitteeNCE/2
ISBN978 0 580 80400 7
PublisherBSI
FormatA4
DeliveryYes
Pages46
File Size967 KB
Price£240.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

The faster, easier way to work with standards


Develop a PAS

Develop a fast-track standardization document in 9-12 months