BS EN 1047-2:2009+A1:2013 - Secure storage units. Classification and methods of test for resistance to fire. Data rooms and data container

BS EN 1047-2:2009+A1:2013

Secure storage units. Classification and methods of test for resistance to fire. Data rooms and data container

Status : Superseded, Withdrawn   Published : January 2010 Replaced By : BS EN 1047-2:2019

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


Data rooms and data containers are fire protection security products whose purpose is to protect temperature and humidity sensitive data media and hardware systems from the effects of fire. These fire resistance products do not provide any defined protection against burglary. Based on these objectives, the CEN/TC 263 Working Group WG2 Fire Resistance unanimously noted at its meeting on 8 March 2012 that the requirement for a certified high security lock according to EN 1300 for data rooms and data containers suggests protection that is not provided and does not reflect the requirements of the market. For the reasons explained above, WG2 unanimously recommended deletion of the requirements for a certified high security lock according to EN 1300 without replacement from EN 1047-2:2009. In the interest of the market, this change in this European Standard shall be implemented very soon via an Amendment to EN 1047-2:2009. The necessary decision shall be taken in a 3 months shortened UAP. The necessary application shall be filed with the CEN/TC 263 via DIN. The draft for Amendment A1 to EN 1047-2:2009 shall be presented to the CEN/TC 263 together with the application for changes in this European Standard.




Standard NumberBS EN 1047-2:2009+A1:2013
TitleSecure storage units. Classification and methods of test for resistance to fire. Data rooms and data container
StatusSuperseded, Withdrawn
Publication Date31 January 2010
Withdrawn Date25 April 2019
Normative References(Required to achieve compliance to this standard)EN 60584-1, EN 1365-2, EN 206-1, EN 61515, EN 1365-1, IEC 61515:1995, EN 1363-1:1999, BS EN 1300:2018, EN 1363-2:1999, IEC 60584-1:1995, EN 1364-1:1999, EN 1300:2018
Informative References(Provided for Information)EN 1047-1
Replaced ByBS EN 1047-2:2019
International RelationshipsEN 1047-2:2009+A1:2013
Amended ByAmendment, August 2013
DescriptorsSecurity storage, Crime prevention devices, Documents, Fire resistance, Fire tests, Safes, Storage furniture, Temperature, Rooms, Layout, Computer hardware, Safety devices, Document storage devices, Specimen preparation, Locks, Classification systems, Data media, Test equipment, Test specimens, Marking, Containers, Data, Dimensions, Humidity
ICS13.220.40
13.310
35.020
Title in FrenchUnités de stockage en lieu sûr. Classification et méthodes d'essai de résistance au feu. Conteneurs et chambres réfractaires
Title in GermanWertbehältnisse. Klassifizierung und Methoden zur Prüfung des Widerstandes gegen Brand. Datensicherungsräume und Datensicherungscontainer
CommitteeGW/2
ISBN978 0 580 79245 8
PublisherBSI
FormatA4
DeliveryYes
Pages38
File Size1.192 MB
Price£214.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Collaborate, Innovate, Accelerate.


Worldwide Standards
We can source any standard from anywhere in the world


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version