BS 7870-3.21:2011 - LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors

BS 7870-3.21:2011

LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors

Status : Current, Under review   Published : December 2011

Format
PDF

Format
HARDCOPY






Standard NumberBS 7870-3.21:2011
TitleLV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors
StatusCurrent, Under review
Publication Date31 December 2011
Confirm Date01 June 2016
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
ReplacesBS 7870-3.21:2001
Amended ByCorrigendum, August 2012
DescriptorsElectrical insulation, Polymers, Sheathed cables, Low voltage, Rated voltage, Power cables, Concentric, Aluminium, Polyethylene, Plastics and rubber technology, Electric cables, Dimensions, Electric conductors, Voltage, Copper, Temperature, Insulated cables, Cable sheaths, Cross-linked materials, Performance, Medium voltage
ICS29.060.20
CommitteeGEL/20/16
ISBN978 0 580 78836 9
PublisherBSI
FormatA4
DeliveryYes
Pages22
File Size692 KB
Price£134.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

Access, view and download standards with multiple user access, across multiple sites with BSOL


Customers who bought this product also bought

  • BS 7870-3.11:2011
    LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
  • BS 7870-3.12:2011
    LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire
  • BS 7870-3.40:2011
    LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors
  • BS 7870-3.22:2011
    LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire