BS EN 55016-2-3:2010+A2:2014 - Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Radiated disturbance measurements

BS EN 55016-2-3:2010+A2:2014

Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Radiated disturbance measurements

Status : Superseded, Withdrawn   Published : July 2010 Replaced By : BS EN 55016-2-3:2017

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


This part of CISPR 16 specifies the methods of measurement of radiated disturbance phenomena in the frequency range of 9 kHz to 18 Ghz. The aspects of measurement uncertainty are specified in CISPR 16‑4‑1 and CISPR 16‑4‑2.

NOTE

In accordance with IEC Guide 107, CISPR 16‑2‑3 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular EMC tests for specific products.




Standard NumberBS EN 55016-2-3:2010+A2:2014
TitleSpecification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Radiated disturbance measurements
StatusSuperseded, Withdrawn
Publication Date31 July 2010
Withdrawn Date30 January 2020
Normative References(Required to achieve compliance to this standard)EN 55014-1:2006, EN 61000-4-21, ISO/IEC Guide 2:2004, CISPR 16-1-4:2010, ISO/IEC Guide 99:2007, CISPR/TR 16-3:2010, EN 55016-1-2:2004, EN 55011:2009, CISPR 16-1-2:2003/A2:2006, CISPR 14-1:2005, EN 55016-1-4:2010, IEC 61140:2001, EN 61000-4-20, CISPR 16-2-1:2008, EN ISO/IEC 17000:2004, CISPR 16-1-2:2003, EN 55022, CISPR 16-4-2, CISPR 16-4-1, IEC 61000-4-20, IEC 61000-4-21, IEC 60050-161:1990/A1:1997, EN 61000-4-3:2006, CISPR 16-1-2:2003/A1:2004, EN 55016-1-1, CISPR/TR 16-3:2010/A1:2012, IEC 60050-161:1990/A2:1998, IEC 60050-151:2001, IEC 60050-161:1990, IEC 61000-4-3:2006/A1:2007, CISPR 16-4-5, EN 55016-4-2, CISPR 16-1-1, CISPR 11:2009, ISO/IEC 17000:2004, EN 55016-2-1:2009, EN 61140:2002, IEC 61000-4-3:2006, CISPR 22:2008
Informative References(Provided for Information)ISO/IEC Guide 99:2007, IEC 61000-4-21, EN 55011:2009, CISPR/TR 16-3:2010/A1:2012, ISO/IEC 17000:2004, IEC 61140:2001, CISPR 22:2008, CISPR 11:2009, ISO/IEC Guide 2:2004, EN ISO/IEC 17000:2004, EN 55022, EN 61140:2002, CISPR/TR 16-3:2010, IEC 60050-151:2001
Replaced ByBS EN 55016-2-3:2017
ReplacesDD CLC/TS 50217:2005, BS EN 55016-2-3:2006
International RelationshipsCISPR 16-2-3:2010/AMD2:2014,EN 55016-2-3:2010/A2:2014
Amended ByAmendment, September 2014; Corrigendum, September 2013
Draft Superseded By11/30244477 DC11/30250903 DC
DescriptorsElectrical measuring instruments, Electric cables, Electric power system disturbances, Radio receivers, Voltage measurement, Electrical wave measurement, Radiofrequencies, Noise (spurious signals), Classification systems, Circuits, Electrical measurement, Electromagnetic compatibility, Electric fields, Radio disturbances, Testing conditions, Test equipment, Television receivers, Emission, Electronic equipment and components, Electromagnetism, Current measurement
ICS33.100.10
33.100.20
Title in FrenchSpécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques. Méthodes de mesure des perturbations et de l'immunité. Mesures des perturbations rayonnées
Title in GermanAnforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit. Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit. Messung der gestrahlten Störaussendung
CommitteeGEL/210/11
ISBN978 0 580 75017 5
PublisherBSI
FormatA4
DeliveryYes
Pages104
File Size3.303 MB
Price£292.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


Customers who bought this product also bought

  • BS EN 55016-1-4:2010+A1:2012
    Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus. Antennas and test sites for radiated disturbance measurements
  • BS EN 55016-2-1:2014
    Specification for radio disturbance and immunity measuring apparatus and methods Methods of measurement of disturbances and immunity. Conducted disturbance measurements
  • BS EN 55016-1-1:2010+A2:2014
    Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus. Measuring apparatus