BS EN 60831-1:2014 - Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V. General. Performance, testing and rating. Safety requirements. Guide for installation and operation

BS EN 60831-1:2014

Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V. General. Performance, testing and rating. Safety requirements. Guide for installation and operation

Status : Current   Published : July 2014

Format
PDF

Format
HARDCOPY



IEC 60831-1:2014 is available as

IEC 60831-1:2014 RLV

which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.



IEC 60831-1:2014 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage up to and including 1 000 V and frequencies of 15 Hz to 60 Hz. This part of IEC 60831 also applies to capacitors intended for use in power filter circuits. Additional definitions, requirements, and tests for power filter capacitors are given in Annex A. The object of this part of IEC 60831 is to:


- formulate uniform rules regarding performances, testing and rating;


- formulate specific safety rules;


- provide a guide for installation and operation. This third edition cancels and replaces the second edition published in 1996 and Amendment 1:2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:


- Updating of the normative references;


- Test conditions have been clarified;


- Thermal stability test has been clarified;


- Maximum permissible voltage and current have been clarified;


- The protection of the environment has been amended with safety concerns and plastic quality requirements.


The contents of the corrigendum of May 2014 have been included in this copy.




Standard NumberBS EN 60831-1:2014
TitleShunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V. General. Performance, testing and rating. Safety requirements. Guide for installation and operation
StatusCurrent
Publication Date31 July 2014
Normative References(Required to achieve compliance to this standard)EN 60269-1:2007, EN 60695-2-12:2010, IEC 60831-2:2014, IEC 60831-2:2013, EN 60831-2:2014, IEC 60695-2-12:2010, IEC 60060-1:2010, EN 61000-4-1:2007, IEC 60269-1:2006, EN 61000-2-2:2002, IEC 61000-2-2:2002, EN 60060-1:2010, IEC 61000-4-1:2006
Informative References(Provided for Information)IEC 60721-2-6:1990, IEC 60050-604:1987, IEC 60110-1:1998, IEC 60996:1989, EN 60143-4, EN 60252-1:2011, EN 61049:1993, IEC 60252-1:2001, EN 60358-1, ANSI C29.9:1983, EN 61048:2006, IEC 60050-436:1990, EN 60143-1, IEC 60358-1, EN 60110-1:1998, EN 60143-3, IEEE Paper PE-009PRD, EN 60060-2:2011, IEC 61071, IEEE Std 824-1994, EN 60143-2, EN 61071, IEC 61048:1991, IEC 60060-2:1994, IEC 61049:1991, IEC 60050-601:1985, IEC 60273:1990
ReplacesBS EN 60831-1:1998, IEC 60831-1:1996
International RelationshipsEN 60831-1:2014,IEC 60831-1:2014,IEC 60831-1:2014/COR1:2014
Draft Superseded By11/30243422 DC
DescriptorsQuality assurance, Formulae (mathematics), Testing conditions, Ratings, Safety measures, Rated frequencies, Thermal testing, Electrical testing, Selection, Classification systems, Power capacitors, Environment (working), Safety devices, Overload (electric), Capacitors, Type testing, Installation, Switches, Impulse-voltage tests, Circuits, Capacitance measurement, Thermal stability, Alternating current, Capacitor banks, Marking, Electromagnetic compatibility, Performance, Rated voltage, Symbols
ICS29.120.99
31.060.70
Title in FrenchCondensateurs shunt de puissance autoregénérateurs pour réseaux à courant alternatif de tension assignée inférieure ou égale à 1 000 V. Généralités. Caractéristiques fonctionnelles, essais et valeurs assignées. Règles de sécurité. Guide d'installation et d'exploitation
Title in GermanSelbstheilende Leistungs-Parallelkondensatoren für Wechselstromanlagen mit einer Bemessungsspannung bis 1 000 V. Allgemeines. Leistungsanforderungen, Prüfung und Bemessung. Sicherheitsanforderungen. Anleitung für Errichtung und Betrieb
CommitteePEL/33
ISBN978 0 580 74781 6
PublisherBSI
FormatA4
DeliveryYes
Pages42
File Size1.328 MB
Price£214.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought

  • BS EN 60831-2:2014
    Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V Ageing test, self-healing test and destruction test