BS EN 50065-1:2011 - Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz. General requirements, frequency bands and electromagnetic disturbances

BS EN 50065-1:2011

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz. General requirements, frequency bands and electromagnetic disturbances

Status : Current   Published : June 2011

Format
PDF

Format
HARDCOPY



This standard applies to electrical equipment using signals in the frequency range 3 kHz to 148,5 kHz to transmit information on low voltage electrical systems, either on the public electricity distribution network or within installations in consumers’ premises. It specifies the frequency bands allocated to the different applications, limits for the terminal output voltage in the operating band and limits for conducted and radiated disturbance. It also gives the methods of measurement. It does not specify the modulation methods, the coding methods or functional features (except those for the prevention of mutual interference). Environmental requirements and tests are not included. NOTE 1 Compliance with this standard does not imply permission to establish communication with locations outside the consumer’s installation or with other consumers through the public electricity distribution network where this would not otherwise be allowed. The object of the standard is to limit mutual influence between transmission equipment in electrical installations and between such equipment and other equipment. In addition this standard is intended to limit interference caused by signal transmission equipment to sensitive electronic equipment. However, complete freedom from such interference cannot be assured. NOTE 2 Designers should consider signalling systems in conformance with this standard when determining immunity for electrical equipment.




Standard NumberBS EN 50065-1:2011
TitleSignalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz. General requirements, frequency bands and electromagnetic disturbances
StatusCurrent
Publication Date30 June 2011
Normative References(Required to achieve compliance to this standard)IEC 60050-161, EN 55016-1-1:2010, CISPR 16-1-1:2010, EN 55016-1-2:2004, EN 55016-1-2:2004/AMD 1:2005, EN 55016-1-2:2004/AMD 2:2006, CISPR 16-1-2:2003, CISPR 16-1-2:2003/AMD 1:2004, CISPR 16-1-2:2003/AMD 2:2006, EN 55016-1-4:2010, CISPR 16-1-4:2010, EN 55016-2-2:2004, EN 55016-2-2:2004/AMD 1:2005, EN 55016-2-2:2004/AMD 2:2005, CISPR 16-2-2:2003, CISPR 16-2-2:2003/AMD 1:2004, CISPR 16-2-2:2003/AMD 2:2005
Informative References(Provided for Information)EN 55022:2006, EN 55022:2006/AMD 1:2007, CISPR 22:2005, CISPR 22:2005/AMD 1:2005, EN 61851-1, IEC 61851-1, 2004/108/EC
ReplacesBS EN 50065-1:2001+A1:2010
International RelationshipsEN 50065-1:2011
Draft Superseded By10/30235496 DC
DescriptorsElectrical installations, Low-voltage installations, Electrical equipment, Signals, Signal transmission, Mains electricity supply, Communication equipment, Frequency bands, Electric power system disturbances, Noise (spurious signals), Radio disturbances, Frequency measurement, Electrical measurement, Electromagnetic radiation
ICS33.040.30
33.100.01
Title in FrenchTransmission de signaux sur les réseaux électriques basse tension dans la bande de fréquences de 3 kHz à 148,5 kHz. Règles générales, bandes de fréquences et perturbations électromagnétiques
Title in GermanSignalübertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz. Allgemeine Anforderungen, Frequenzbänder und elektromagnetische Störungen
CommitteePEL/205
ISBN978 0 580 73061 0
PublisherBSI
FormatA4
DeliveryYes
Pages36
File Size2.487 MB
Price£214.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Collaborate, Innovate, Accelerate.


Worldwide Standards
We can source any standard from anywhere in the world


Customers who bought this product also bought

  • BS EN 50065-7:2001
    Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 kHz Equipment impedance
  • BS EN 61000-6-4:2007+A1:2011
    Electromagnetic compatibility (EMC) Generic standards. Emission standard for industrial environments
  • BS EN 50065-2-3:2003
    Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148.5 Khz Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors
  • BS EN 50065-2-1:2003
    Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments