BS EN 55016-1-5:2015 - Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

BS EN 55016-1-5:2015

Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

Status : Current, Revised, Superseded   Published : February 2015 Replaced By : BS EN 55016-1-5:2015+A1:2017

Format
PDF

Format
HARDCOPY



CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:


- site validation methods for other sites covered in CISPR 16-1-6 are added;


- smaller step sizes are specified for swept frequency measurements;


- the minimum ground plane size is increased;


- and other miscellaneous technical and editorial refinements are included. Keywords: electromagnetic compatibility




Standard NumberBS EN 55016-1-5:2015
TitleSpecification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
StatusCurrent, Revised, Superseded
Publication Date28 February 2015
Normative References(Required to achieve compliance to this standard)CISPR 16-1-4:2010, CISPR 16-1-6:2014, EN 55016-1-4:2010, EN 55016-1-4:2010+A1:2012, CISPR 16-1-4:2010+A1:2012, EN 55016-1-6:2015, IEC 60050
Informative References(Provided for Information)EN 55016-2-3:2010, CISPR 16-1-1:2010/AMD 1:2010, EN 55016-2-3:2010/A1:2010, CISPR 16-2-3:2010/AMD 1:2010, EN 55016-4-2, CISPR 16-1-1:2010, ANSI C63.5-2006, EN 55016-1-1:2010, EN 55016-1-1:2010/A1:2010, JCGM 200:2012, ANSI C63.7-2005, CISPR 16-2-3:2010, CISPR 16-4
Replaced ByBS EN 55016-1-5:2015+A1:2017
ReplacesBS EN 55016-1-5:2004+A1:2012
International RelationshipsEN 55016-1-5:2015,CISPR 16-1-5:2014
Draft Superseded By10/30232210 DC
DescriptorsEmission measurement, Electric fields, Antennas, Electrical wave measurement, Radio receivers, Voltage measurement, Electrical measurement, Test equipment, Electromagnetism, Radio disturbances, Electromagnetic radiation, Radio antennas, Electromagnetic compatibility, Radiofrequencies, Electrical measuring instruments, Calibration, Electric power systems, Voltmeters, Noise (spurious signals), Current measurement
ICS33.100.10
33.100.20
Title in FrenchSpécification des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques. Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques. Emplacements d'étalonnage d'antenne et emplacements d'essai de référence pour la plage comprise entre 5 MHz et 18 GHz
Title in GermanAnforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit. Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit. Messplätze für die Antennenkalibrierung und Referenz-Messplätze für den Frequenzbereich von 5 MHz bis 18 GHz
CommitteeGEL/210/11
ISBN978 0 580 72337 7
PublisherBSI
FormatA4
DeliveryYes
Pages98
File Size2.397 MB
Price£274.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Collaborate, Innovate, Accelerate.


Worldwide Standards
We can source any standard from anywhere in the world