IEC TS 60695-6-30:2013 - Fire hazard testing. Smoke obscuration. Small-scale static method. Apparatus
Maintenance will be taking place for Shop on Friday 21st February between 17:00 and 19:00 UK time. Shop will be unavailable during this time or will have limited functionality. Please accept our apologies for any inconvenience caused during this essential maintenance.

IEC TS 60695-6-30:2013

Fire hazard testing. Smoke obscuration. Small-scale static method. Apparatus

Status : Current  

Format
PDF

Format
HARDCOPY



IEC/TS 60695-2-30:2013 describes the apparatus, calibration procedures and basic experimental procedures for the determination of the specific optical density of smoke produced by materials exposed vertically to a radiant heat source with or without the application of a pilot flame. The test specimens are of a defined size. The determination of the optical density is carried out in a pressure-controlled chamber previously calibrated with reference materials. The test methods are only applicable to flat, solid, non-metallic test specimens, of materials used in electrotechnical products. This technical specification does not provide a classification system for the behaviour of materials. The test methods are not applicable for materials that melt and flow away from the direct impingement of heat flux. The test methods are not recommended for further development for electrotechnical products nor are they recommended as the basis for regulation or other controls on smoke release due to the limitations of the physical fire model and the test specimen geometry - see Clause 4. This second edition of IEC/TS 60695-6-30 cancels and replaces the first edition published in 1996. It constitutes a technical revision. The main changes with respect to the previous edition are as follows:


- This publication is to be re-designated as a technical specification.


- The title has been modified to align with the IEC Directives.


- The FOREWORD has been revised and updated.


- An INTRODUCTION has been added.


- The Scope has been updated.


- The normative references have been updated.


- The terms and definitions have been updated.


- Clause 4: Relevance of test data and special observations has been revised.


- Detailed editorial updates have been added throughout the document.


It has the status of a basic safety publication in accordance with IEC Guide 104 and ISO/IEC Guide 51. Keywords: Smoke obscuration, Fire Hazard.



This publication is to be read in conjunction with

IEC 60695-6-31:2013

.




Standard NumberIEC TS 60695-6-30:2013
TitleFire hazard testing. Smoke obscuration. Small-scale static method. Apparatus
StatusCurrent
Withdrawn Date10 July 2015
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
ICS29.020
CommitteeGEL/89
ISBN978-2-83220-695-9
PublisherIEC
FormatA4
DeliveryYes
Pages84
File Size2.612 MB
Price£164.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Collaborate, Innovate, Accelerate.


Worldwide Standards
We can source any standard from anywhere in the world