BS EN 55016-1-2:2004+A2:2006 - Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Ancillary equipment. Conducted disturbances – BSI British Standards

BS EN 55016-1-2:2004+A2:2006

Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Ancillary equipment. Conducted disturbances

Status : Revised, Superseded, Withdrawn   Published : January 2005 Replaced By : BS EN 55016-1-2:2014

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


BS EN 55016-1-2 is a European standard that specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz.

Specifications for ancillary apparatus are included for: artificial mains networks, current and voltage probes and coupling units for current injection on cables.

The requirements of this publication shall be complied with at all frequencies and for all levels f radio disturbance voltages and currents within the CISPR indicating range of the measuring equipment.

Methods of measurement are covered in Part 2, and further information on radio disturbance is given in Part 3 of BS EN 55016

BS EN 55016-1-2:2004 replaces BS CISPR 16-1:1999 which remains current.




Standard NumberBS EN 55016-1-2:2004+A2:2006
TitleSpecification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Ancillary equipment. Conducted disturbances
StatusRevised, Superseded, Withdrawn
Publication Date21 January 2005
Withdrawn Date25 April 2017
Normative References(Required to achieve compliance to this standard)CISPR 14-1:2000, CISPR 16-1-1:2003, CISPR 16-2-1:2003, CISPR/TR 16-3:2003, CISPR/TR 16-4-1:2003, CISPR 16-4-2:2003, IEC 60050-161:1990, EN 55014-1:2000, EN 55016-1-1:2004, EN 55016-2-1:2004, EN 55016-4-2 2004
Informative References(Provided for Information)No other standards are informatively referenced
Replaced ByBS EN 55016-1-2:2014
ReplacesBS CISPR 16-1:1999, CISPR 16-1:1999
International RelationshipsCISPR 16-1-2:2003,EN 55016-1-2:2004
Amended ByAMD 15694, April 2006 (not available separately). AMD 16936, February 2007 (not available separately). Corrigendum, April 2010.
Draft Superseded By00/248013 DC02/208871 DC
DescriptorsRadio disturbances, Noise (spurious signals), Radiofrequencies, Electromagnetic compatibility, Electrical measurement, Electrical wave measurement, Test equipment, Electrical measuring instruments, Electrical conductance, Electric power systems, Electric cables, Voltage measurement, Voltmeters, Current measurement, Probes, Electric fields, Electromagnetism Immunity tests
ICS33.100.20
33.100.10
Title in FrenchSpécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques. Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques. Matériels auxiliaires. Perturbations conduites
Title in GermanAnforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit. Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit. Zusatz-/Hilfseinrichtungen. Leitungsgeführte Störaussendung
CommitteeGEL/210/11
ISBN978 0 580 66792 3
PublisherBSI
FormatA4
DeliveryNo
Pages80
File Size4.018 MB
Price£274.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Worldwide Standards
We can source any standard from anywhere in the world


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version