PD IEC/TR 62222:2012 - Fire performance of communication cables installed in buildings
Essential maintenance work will be carried out on BSI Shop over the weekend of 12 and 13 June 2021. BSI Shop will be operational during this time but you might experience slowness for a very brief period of time. Please accept our apologies for any inconvenience this may cause.

PD IEC/TR 62222:2012

Fire performance of communication cables installed in buildings

Status : Superseded, Withdrawn   Published : April 2013 Replaced By : PD IEC TR 62222:2021

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001


IEC/TR 62222:2012 provides recommendations for the requirements and test methods to be specified for the fire performance of communication cables when installed in buildings. The recommendations relate to typical applications and installation practices for copper and optical cables in buildings. This TechnicalReport includes an assessment of the fire hazards presented by such installations, and describes fire scenarios that have been established and the appropriate cable fire performances to mitigate these hazards. ISO/IEC 14763-2 recommends installation methods which,together with this Technical Report, provide guidelines for improving safety during fire. The recommendations also take into account legislation and regulation applicable to the fire performance of cables, an assessment of known test methods and their ability to measure the recommended fire performance. Power cables are usually segregated from communication cables for electrical safety and installed differently so they have not been addressed in this Technical Report.




Standard NumberPD IEC/TR 62222:2012
TitleFire performance of communication cables installed in buildings
StatusSuperseded, Withdrawn
Publication Date30 April 2013
Withdrawn Date03 February 2021
Normative References(Required to achieve compliance to this standard)IEC 60754-1, IEC 60754, IEC 60695-5-1, IEC 60794, IEC 60695-1-10:2009, ISO 13571, IEC 60332-3, IEC 61034, CSA FT4, IEC 60332-1-3, BS 7671, IEC 60332-1, IEC 60695-7-1, IEC/TR 60695-8-2, IEC 61156, IEC 60695-6-2, UL 1685, EN 13823, IEC 60332-2-2, EN 13501-1:2018, BS EN 13501-1:2018, NFPA 262, IEC/TS 60695-5-2, UL 1666, EN 50289-4-11, IEC 60332-3-24, EN 50267-2-3, ISO/IEC 13943, EN 50174-2, IEC 62012-1, IEC 60695-6-1, ISO/IEC 14763, IEC 60332-2, IEC 60754-2, IEC 60332-1-2, IEC 60695-1-11, ISO/IEC 11801, IEC 61034-2:2005, IEC 60695-7-3, IEC/TS 60695-9-2, IEC 60695-9-1, IEC 61034-1:2005, IEC 60695-7-2, ISO 9705, ISO 19706:2011, EN 50399, IEC 60695, IEC 60695-8-1, UL VW-1, CSA FT6
Informative References(Provided for Information)IEC 60695-5-3
Replaced ByPD IEC TR 62222:2021
ReplacesPD IEC/TR 62222:2005
International RelationshipsIEC TR 62222:2012
Draft Superseded By09/30193524 DC
DescriptorsFire tests, Smoke, Risk assessment, Flammability, Electric cables, Performance, Buildings, Communication cables, Ignitability, Fire safety, Fire safety in buildings, Fibre optic cables
ICS13.220.40
33.120.20
Title in FrenchTenue au feu des câbles de communication installés dans les bâtiments
CommitteeEPL/46
ISBN978 0 580 65457 2
PublisherBSI
FormatA4
DeliveryYes
Pages48
File Size1.225 MB
Price£246.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

Access, view and download standards with multiple user access, across multiple sites with BSOL


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version