1.1 Product definition This specification contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a fully installed blown fibre protected microduct closure must meet in order for it to be categorised as an EN standard product. These products are suitable for installation of and use with microduct fibre units, microduct optical fibre cables, microduct and protected microduct as defined within EN 60794-5. 1.2 Operating environment The tests selected combined with the severities and duration are representative of an outside plant for subterranean and/or aerial environment defined by: - ETSI EN 300 019 series: Class 8.1: underground locations (without earthquake requirement); - EN 61753-1: Category S: subterranean environment; Category A: aerial environment. 1.3 Reliability Whilst the anticipated service life expectancy of the product in this environment is a minimum of 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.4 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme. 1.5 Allowed fibre and cable types This closure standard covers all IEC standard optical fibre microducts, and protected microducts with their various fibre capacities, types and designs. This includes, but is not limited to, optical fibre cable standard EN 60794-5. This product specification has only considered protected microduct cables containing microducts of same outside diameters. There are other hybrid protected microduct cables with microducts of differing OD's, with too many variants to be included in this PS. 1.6 Allowed microduct connector types This closure standard covers all EN standard microduct connectors, including: straight, reducer/enlarger stem, reducer/enlarger, close down, liquid block, liquid block with barb end, and end stop connectors. This includes, but is not limited to, EN 50411-2-8. 1.7 Microduct storage constraints Microduct excess storage is not required in all air blown fibre closures. Some closure types do not have sufficient internal space to provide storage. The need for microduct storage is provided inside the closure when opened, typically to ensure that there is enough microduct to fulfil the following functions: - remove the coiled microduct attached to the 'closedown' connectors, to a remote location, close to blowing equipment, in the process uncoiling the microducts to aid blowing; - provide additional microduct if repeated cut backs for connectors are planned or likely to be fitted throughout the closure life. The minimum microduct storage bend radius is based on the outside diameter and material selection, typically based on 12 times the outside diameter (below 8 mm) and 20 times above. During fibre blowing the bend radius is typically 20 times the microduct diameter.




Standard NumberBS EN 50411-2-5:2009
TitleFibre organisers and closures to be used in optical fibre communication systems. Product specifications. Sealed closures for air blown fibre microduct, type 1, for category S & A
StatusCurrent, Under review
Publication Date31 July 2009
Normative References(Required to achieve compliance to this standard)IEC 61300-2-26, EN 61300-2-23:1997, EN 61300-2-38:2006, IEC 61300-2-5, EN 61300-3-28, EN 61300-3-1, EN 61300-2-10, EN 61300-2-26, EN 60068-2-10, EN 61300-2-34, EN 61300-2-4, ETSI EN 300019, IEC 61300-2-10, EN IEC 61753-1:2018, IEC 61753-1:2018, ISO 1998-1, BS EN 61753-1, BS EN IEC 61753-1:2018, IEC 61300-2-23:1995, EN 61300-2-5, IEC 61300-2-38:2006, IEC 61300-2-34, IEC 61300-2-4, EN 61300-2-12:2005, IEC 61300-2-12:2005, IEC 61300-2-37, IEC 61300-2-33, EN 60794-1-2:2003, IEC 61300-3-3:2003, IEC 61300, IEC 60794-5, EN 61300, EN 61300-2-1, IEC 61300-2-1, EN 61300-2-37, EN 61300-3-3:2003, EN 60794-5, EN 61300-2-33, IEC 61300-2-22, IEC 60068-2-10, EN 61300-2-22, IEC 61300-3-28, IEC 61300-3-1, IEC 60794-1-2:2003, EN 50411-2-8, EN 590
Informative References(Provided for Information)EN 61758-1, IEC 61756-1, EN 60529, IEC 60529, IEC 61758-1, EN 61756-1, EN 60793-2-50, IEC 60793-2-50
International RelationshipsEN 50411-2-5:2009,IEC 60947-7-3:2009
Draft Superseded By06/30157058 DC
DescriptorsSealed, Closures, Performance, Communication cables, Mechanical properties of materials, Specification (approval), Dimensions, Fibre optics, Optical properties of materials, Optical fibres, Optical communication systems, Fibre optic cables, Environmental testing, Fibre optic connectors
ICS33.180.20
Title in FrenchOrganiseurs et boîtiers de fibres à utiliser dans les systèmes de communication par fibres optiques. Spécifications de produits. Boîtiers scellés pour microconduits de fibres soufflées à l'air comprimé, pour les catégories S & A
Title in GermanLWL-Spleißkassetten und -Muffen für die Anwendung in LWLKommunikationssystemen. Produktnormen. Abgedichtete LWL-Muffen für ABF-Mikrorohre, Bauart 1, für die Kategorien S und A
CommitteeGEL/86/2
ISBN978 0 580 64513 6
PublisherBSI
FormatA4
DeliveryYes
Pages50
File Size784 KB
Price£240.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


BSOL

The faster, easier way to work with standards


Develop a PAS

Develop a fast-track standardization document in 9-12 months