BS EN 50223:2010 - Stationary electrostatic application equipment for ignitable flock material. Safety requirements

Find Similar Items

This product falls into the following categories.

You may find similar items within these categories by selecting from the choices below:

BS EN 50223:2010

Stationary electrostatic application equipment for ignitable flock material. Safety requirements

Status : Revised, Superseded, Withdrawn   Published : April 2011 Replaced By : BS EN 50223:2015

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


1.1 This European Standard specifies requirements for automatic electrostatic flock application equipment which is designed for applying ignitable flock which may form explosive atmospheres in the flock application area. In this context a distinction is made between flock application devices which due to their type of construction comply with the requirements as laid down in EN 50050 as applicable, and those for which higher discharge energies are stipulated. This European Standard also specifies the constructional requirements for a safe operation of the stationary equipment of flock application booths, including the electrical installations and the accessories. This European Standard deals with all significant hazards, hazardous situations and events relevant to flock application booths, when they are used as intended and under conditions which are foreseeable as malfunction by the manufacturer (see Clause 4). 1.2 This European Standard considers four types of electrostatic flock systems. For more details, see Table 1. 1.3 This European Standard deals with those hazards occurring during stationary automatic electrostatic flocking. Among these hazards are, above all, ignition hazards of the generated explosive atmosphere and hazard to persons. 1.4 The stationary equipment dealt with in this European Standard is considered to be equipment of group II, category 3D for the use in areas with potential explosion hazards of zone 22. 1.5 In cases of hybrid mixtures, the stationary equipment dealt with in this European Standard is also considered as equipment of group II, category 3G for the use in areas with potential explosion hazard of zone 2. 1.6 This European Standard is not applicable for - flock systems operated with AC voltage, - the application system for liquid or pasty substances (e.g. adhesives, primer), - the cleaning of flock application booths, - the storage and handling of ignitable substances outside the coating plant.




Standard NumberBS EN 50223:2010
TitleStationary electrostatic application equipment for ignitable flock material. Safety requirements
StatusRevised, Superseded, Withdrawn
Publication Date30 April 2011
Withdrawn Date31 July 2015
Cross ReferencesEN 50050:2006, EN 60079-0:2006, IEC 60079-0:2004, EN 60204-1:2006, EN 60204-1:2006+A1:2009, IEC 60204-1:2005, IEC 60204-1:2005/AMD 1:2008, EN 60529:1991, EN 60529:1991/A1:2000, IEC 60529:1989, IEC 60529:1989/AMD 1:1999, EN 61241-0:2006, IEC 61241-0:2004, IEC 61241-0:2004/Corrigendum:2005, EN 61241-10:2004, IEC 61241-10:2004, EN 61340-4-1:2004, IEC 61340-4-1:2003, EN 62061:2005, IEC 62061:2005, EN 619, EN 746-1:1997+A1:2009, EN 953, EN 981, EN 1037, EN 1081:1998, EN 1127-1:2007, EN 1149-5, EN 12445, EN 12453, EN 12635, EN 12978, EN 13463-1:2009, EN 13478:2001+A1:2008, EN 13501-1, EN 14373, EN 14460, EN 14462, EN 14491, EN 14797, EN 14986, EN 15089, EN ISO 12100-1:2003+A1:2009, ISO 12100-1:2003+A1:2009, EN ISO 12100-2:2003+A1:2009, ISO 12100-2:2003+A1:2009, EN ISO 13849-1, ISO 13849-1, EN ISO 13850, ISO 13850, EN ISO 14122-2, ISO 14122-2, EN ISO 14122-3, ISO 14122-3, EN ISO 14122-4, ISO 14122-4, EN ISO 20344:2004+A1:2007, ISO 20344:2004+A1:2007, ISO 8421-3:1989, EN 60079-2, IEC 60079-2, EN 60079-6, IEC 60079-6, EN 60079-7, IEC 60079-7, EN 60079-11, IEC 60079-11, EN 60079-15, IE
Replaced ByBS EN 50223:2015
ReplacesBS EN 50223:2001
International RelationshipsEN 50223:2010
Draft Superseded By08/30180312 DC
DescriptorsProtected electrical equipment, High-voltage equipment, Automatic, Flammable atmospheres, Coating processes, Instructions for use, Electrostatic devices, Electrical testing, High-voltage tests, Flock, Classification systems, Marking, Spraying (coating), Electrical safety, Adhesives, Antistatic materials, Explosive atmospheres, Flammable materials, Sprayers, Spray guns
ICS29.260.20
87.100
Title in FrenchMatériel fixe de projection électrostatique de flock ignitable. Exigences de sécurité
Title in GermanStationäre elektrostatische Flockanlagen für entzündbaren Flock. Sicherheitsanforderungen
CommitteeEXL/31
ISBN978 0 580 62642 5
PublisherBSI
FormatA4
DeliveryNo
Pages52
File Size784 KB
Price£254.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


BSOL

The faster, easier way to work with standards