BS EN 61000-4-17:1999+A2:2009, IEC 61000-4-17:1999 - Electromagnetic compatibility (EMC). Testing and measurement techniques. Ripple on d.c. input power port immunity test – BSI British Standards

BS EN 61000-4-17:1999+A2:2009, IEC 61000-4-17:1999

Electromagnetic compatibility (EMC). Testing and measurement techniques. Ripple on d.c. input power port immunity test

Status : Current   Published : November 1999

Format
PDF

Format
HARDCOPY



BS EN 61000-4-17:1999+A2:2009, IEC 61000-4-17:1999 Electromagnetic compatibility (EMC). Testing and measurement techniques. Ripple on d.c. input power port immunity test

BS EN 61000-4-17 establishes a common and reproducible basis for testing, in a laboratory, electrical and electronic equipment when subjected to ripple voltages such as those generated by rectifier systems and/or auxiliary service battery chargers overlaying on d.c. power supply sources.

BS EN 61000-4-17 defines:

– Test voltage waveform;
– Range of test levels;
– Test generator;
– Test set-up;
– Test procedure.

BS EN 61000-4-17 defines test methods for immunity to ripple at the d.c. input power port of electrical or electronic equipment.

BS EN 61000-4-17 is applicable to low-voltage d.c. power ports of equipment supplied by external rectifier systems, or batteries which are being charged.

The test described in BS EN 61000-4-17 applies to electrical or electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test (EUT) rated power is greater than the test generator capacity specified in clause 6.

This test does not apply to equipment connected to battery charger systems incorporating switch mode converters.

BS EN 61000-4-17 does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users or manufacturers of equipment) remain responsible for the appropriate choice of the test and the severity level to be applied to their equipment.

Dedicated test procedures are in use for testing specific categories of electrical or electronic equipment, e.g. equipment connected to d.c. supply network of telephone switching centres; the related product committees should evaluate the relevance and applicability of the test procedure specified in this basic standard.

Contents of BS EN 61000-4-17:

Scope
2 Normative references
3 General
4 Definitions
5 Test levels and waveform
6 Test generator
6.1 Characteristics and performance of the generator
6.2 Verification of the characteristics of the generator
7 Test set-up
8 Test procedure
8.1 Laboratory reference conditions
8.1.1 Climatic conditions
8.1.2 Electromagnetic conditions
8.2 Execution of the test
9 Evaluation of test results
10 Test report
Annex A (informative) Information on the phenomenon

 




Standard NumberBS EN 61000-4-17:1999+A2:2009, IEC 61000-4-17:1999
TitleElectromagnetic compatibility (EMC). Testing and measurement techniques. Ripple on d.c. input power port immunity test
StatusCurrent
Publication Date15 November 1999
Normative References(Required to achieve compliance to this standard)IEC 60050-161, EN 60068-1:1994, IEC 60068-1
Informative References(Provided for Information)No other standards are informatively referenced
International RelationshipsEN 61000-4-17 Amd 2 (02/09) (I,IEC 61000-4-17:1999/AMD2:2008
Amended ByAMD 15274
Amendment, May 2010; Amendment, July 2004
DescriptorsElectric current, Electrical equipment, Verification, Electric generators, Electromagnetism, Low voltage, Electromagnetic compatibility, Direct current, Testing conditions, Test equipment, Electric power system disturbances, Electrical testing, Surges (electrical), Rated current, Field strength (electric), Voltage, Environment (working), Electromagnetic fields, Electric fields, Performance, Electronic equipment and components, Wave properties and phenomena, Electric cells, Electromagnetic radiation, Graphic representation, Electrical wave measurement, Magnetic fields Immunity tests
ICS33.100.20
Title in FrenchCompatibilité électromagnétique (CEM). Techniques d'essai et de mesure. Essai d'immunité à l'ondulation résiduelle sur entrée de puissance à courant continu
Title in GermanElektromagnetische Verträglichkeit (EMV). Prüf- und Meßverfahren. Prüfung der Störfestigkeit gegen Wechselanteile der Spannung an Gleichstrom-Netzanschlüssen
CommitteeGEL/210/11
ISBN978 0 580 61449 1
PublisherBSI
FormatA4
DeliveryYes
Pages18
File Size691 KB
Price£130.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought

  • BS EN 61000-4-29:2001, IEC 61000-4-29:2000
    Electromagnetic compatibility (EMC). Testing and measurement techniques Testing and measurement techniques. Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
  • BS EN 61000-6-4:2007+A1:2011
    Electromagnetic compatibility (EMC) Generic standards. Emission standard for industrial environments