Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V, having low emission of smoke and corrosive gases when affected by fire

Status : Revised, Superseded, Withdrawn   Published : September 1997 Replaced By : BS 6724:2016

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


BS 6724 : 1997 + A3:2008 specifies requirements for construction and describes methods of test for armoured cables with thermosetting insulation of rated voltages 600/1 000 V and 1 900/3 300 V which, when assessed by the specified tests, produce lower levels of smoke and corrosive products under exposure to fire compared with cables conforming to BS 5467. Cables specified in this standard are intended for use in fixed installations in industrial areas, buildings and similar applications.

In this standard, the level of corrosive (and acid) gases is determined by measurement of hydrochloric acid (HCl) in accordance with BS EN 50267-2-1. The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90 °C and for a maximum short-circuit conductor temperature of 250 °C.

The cables specified in the standard are all wire armoured and oversheathed, as follows:
a) 600/1 000 V
b) 1 900/3 300 V.

This amendment makes changes to the scope so as to reflect those cable types in common use in the construction and industrial sector. The range of 600/1 000 V cables has been widened by adding 400 mm2 sizes for four-core cables, and four-core cables with reduced neutral and a range of 5-core cables. The range of multicore auxiliary cables has been increased up to 48 core.

BS 6724:1997+A3:2008 supersedes BS 6724:1997+A2:2005, which is withdrawn.




Standard NumberBS 6724:1997+A3:2008
TitleElectric cables. Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V, having low emission of smoke and corrosive gases when affected by fire
StatusRevised, Superseded, Withdrawn
Publication Date15 September 1997
Confirm Date02 August 2013
Withdrawn Date30 April 2017
Normative References(Required to achieve compliance to this standard)BS 5099:2004, BS 7655-1.2:1993, BS 7655-1.3:1993, BS 7655-6.1:1994, BS EN 10002-1:1990, BS EN 10244-2, BS EN 50266-2-4, BS EN 50267-2-1, BS EN 50363-5, BS EN 60228, BS EN 60332-1-2:2004, BS EN 60811-1-1:1995, BS EN 60811-1-2:1995, BS EN 60811-1-3:1995, BS EN 61034-2, BS EN 62230, IEC 60050-461
Informative References(Provided for Information)BS 5467:1997, BS 7671:1992, BS EN 50396:2005, BS EN 60079-14, HD 308 S2, IEC 60183:1984, ERA Publication 69-30 Part V
Replaced ByBS 6724:2016
ReplacesBS 6724:1990
Amended ByAMD 15652
AMD 14206, February 2004. Amendment, June 2008. Amends and replaces BS 6724:1997.
Draft Superseded By07/30169735 DC
DescriptorsArmoured cables, Sheathed cables, Insulated cables, Power cables, Single-core cables, Multicore cables, Electric cables, Electric power systems, Smoke, Combustion products, Rated voltage, Electric conductors, Aluminium, Copper, Thermosetting polymers, Polyethylene, Ethylene-propylene rubber, Electrical insulating materials, Fire safety, Identification methods, Colour codes, Marking, Diameter, Thickness, Performance, Testing conditions, Specimen preparation, Electrical testing, Type testing, Selection, Installation, Tensile strength, Elongation at fracture, Dimensions, Wear tests, Fire tests, Test equipment, Electrical resistance, Fire-resistant materials
ICS29.060.20
Title in FrenchSpecification des cables electriques armees de 600/1000 V et 1900/3300 V d'isolation thermodurcissable et faible emission de fumee et gaz corrosifs lors d'un incendie
Title in GermanSpezifikation fuer 600/1000 V und 1900/3300 abgeschirmte Elektrokabel mit waermebestaendiger Isolierung und niedriger Rauchemission und korrosiven Gasen wenn von Feuer beeinflusst.
CommitteeGEL/20/17
ISBN978 0 580 59921 7
PublisherBSI
FormatA4
DeliveryNo
Pages48
File Size3.473 MB
Price£240.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


Collaborate, Innovate, Accelerate.


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought

  • BS 6469-99-1:1992
    Insulating and sheathing materials of electric cables Test methods used in the United Kingdom but not specified in BS EN 60811
  • BS EN 60228:2005
    Conductors of insulated cables
  • BS 7655-0:2006
    Specification for insulating and sheathing materials for cables General introduction
  • BS 7655-1.3:2000
    Specification for insulating and sheathing materials for cables. Elastomeric insulating compounds XLPE