BS EN 1020:2009 - Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products – BSI British Standards

BS EN 1020:2009

Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products

Status : Withdrawn, Superseded   Published : January 2010 Replaced By : BS EN 17082:2019

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


BS EN 1020:2009 Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products

BS EN 1020 is a European Standard which specifies the requirements and test methods for the safety and efficiency of nondomestic gas-fired air heaters having a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This includes appliances having forced draught burners.

BS EN 1020  applies to Type B12, B13, B14, B22, B23, B42, B43, B44, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with a heat input not exceeding 300 kW (based on net calorific value) intended for use in other than single unit residential dwellings. It also applies to appliances intended for outdoor installation.

Provision of the heated air may be by means of ducting or may be directly into the heated space.

For Type C62 and C63 appliances, this European Standard only applies when such appliances are intended for final installation in a similar manner to Type C3 appliances.

Contents of BS EN 1020:

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification of systems
5 Constructional requirements
6 Operational requirements
7 Test methods
8 Marking and instructions
9 Evaluation of conformity of POCED's and their associated terminals
Annex A (informative) National situations


 




Standard NumberBS EN 1020:2009
TitleNon-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products
StatusWithdrawn, Superseded
Publication Date31 January 2010
Confirm Date23 September 2014
Withdrawn Date05 November 2019
Normative References(Required to achieve compliance to this standard)EN ISO 3166-1, EN 88-1, ISO 3166-1:2006, IEC 61058-1:2000, IEC 60730-2-9:2000, EN 161, IEC 60730-1:1999, ISO 7005-3, IEC 60335-2-102:2004, EN 60730-1, ISO 6976:1995/Corrigendum 3:1999, EN 126, IEC 60335-1:2001, EN 10226-1, EN 60335-1:2002, ISO 6976:1995, ISO 228-1:2000, ISO 1182:1990, EN 298:2003, EN 60529:1991, IEC 60584-1:1995, ISO 228-1:1994, EN 60584-1, ISO 7-1, EN 437:2003, EN 1859:2000, IEC 60730-2-9:2002, EN 125, EN 60335-2-102, IEC 61058-1:2000/AMD 1:2001, EN ISO 6976, EN 60584-2, CR 1404, EN 10226-2, ISO 6976:1995/Corrigendum 2:1997, IEC 60584-2:1982, ISO 6976:1995/Corrigendum 1:1997, IEC 60584-2:1982/AMD 1:1989, EN 12067-1, ISO 7005-1, IEC 60529:1989, ISO 7005-2, EN 61058-1, EN ISO 228-1, EN 257
Informative References(Provided for Information)EN 60730-2-1:1997, ISO 2859-1, EN 61558-2-6:1998, EN 676, IEC 60730-2-1:1989, IEC 61558-2-6:1997
Replaced ByBS EN 17082:2019
ReplacesBS EN 1020:1998
International RelationshipsEN 1020:2009
Draft Superseded By07/30163039 DC
DescriptorsDesignations, Flames, Accuracy, Combustion products, Controllers, Industrial, Flues, Ignition, Flow regulators, Electrical testing, Temperature, Burners, Maintenance, Marking, Automatic, Equipment safety, Design, Performance, Safety measures, Air heaters, Artificial weathering tests, Leak tests, Commissioning, Testing conditions, Performance testing, Efficiency, Cut-out devices, Ignition systems (heat engineering), Safety devices, Control devices, Electrical safety, Test pressure, Instructions for use, Convection heaters, Stability, Classification systems, Thermostats, Pipe connections, Conversion, Heaters, Fire safety, Heating equipment, Gas space heating, Commercial, Gas-powered devices
ICS97.100.20
Title in FrenchGénérateurs d'air chaud à convection forcée utilisant les combustibles gazeux pour le chauffage de locaux autres que l'habitat individuel de débit calorifique sur PCI inférieur ou égal à 300 kW, comportant un ventilateur pour aider l'alimentation en air comburant et/ou l'évacuation des produits de combustion
Title in GermanGasbefeuerte Warmlufterzeuger mit verstärkter Konvektion für den nicht-häuslichen Gebrauch mit einer Nennwärmebelastung nicht über 300 kW, mit Gebläse zur Beförderung der Verbrennungsluft und/oder der Abgase
CommitteeGSE/20/4
ISBN978 0 580 58504 3
PublisherBSI
FormatA4
DeliveryYes
Pages156
File Size1.944 MB
Price£342.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

The faster, easier way to work with standards