BS EN 61391-2:2010 - Ultrasonics. Pulse-echo scanners. Measurement of maximum depth of penetration and local dynamic range

BS EN 61391-2:2010

Ultrasonics. Pulse-echo scanners. Measurement of maximum depth of penetration and local dynamic range

Status : Current   Published : July 2010

Format
PDF

Format
HARDCOPY



IEC 61391-2:2010 defines terms and specifies methods for measuring the maximum depth of penetration and the local dynamic range of real time ultrasound B MODE scanners. The types of transducers used with these scanners include:


- mechanical probes;


- electronic phased arrays;


- linear arrays;


- curved arrays;


- two-dimensional arrays;


- three-dimensional scanning probes based on a combination of the above types.


All scanners considered are based on pulse-echo techniques. The test methodology is applicable for transducers operating in the 1 MHz to 15 MHz frequency range operating both in fundamental mode and in harmonic modes that extend to 15 MHz. However, testing of harmonic modes above 15 MHz is not covered by this standard.




Standard NumberBS EN 61391-2:2010
TitleUltrasonics. Pulse-echo scanners. Measurement of maximum depth of penetration and local dynamic range
StatusCurrent
Publication Date31 July 2010
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
International RelationshipsEN 61391-2:2010,EN 61747-2-2:2004,IEC 61391-2:2010
Draft Superseded By07/30161032 DC
DescriptorsDimensional measurement, Maximum, Clinical investigation instruments, Working range, Measuring instruments, Ultrasound scanners, Ultrasonic devices, Scanners, Image processing (computer), Ultrasonics, Ultrasonic medical apparatus, Dynamics, Depth measurement, Patient scanners
ICS11.040.55
17.140.50
Title in FrenchUltrasons. Scanners à impulsion et écho. Mesure de la profondeur maximale de pénétration et de la plage dynamique locale
Title in GermanUltraschall. Impuls-Echo-Scanner. Messung der maximalen Eindringtiefe und des lokalen Dynamikbereichs
CommitteeEPL/87
ISBN978 0 580 58266 0
PublisherBSI
FormatA4
DeliveryYes
Pages42
File Size693 KB
Price£214.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world