BS EN 61557-12:2008 - Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Performance measuring and monitoring devices (PMD)

BS EN 61557-12:2008

Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Performance measuring and monitoring devices (PMD)

Status : Current, Work in hand   Published : June 2008

Format
PDF

Format
HARDCOPY



Specifies requirements for combined performance measuring and monitoring devices that measure and monitor the electrical parameters within electrical distribution systems. These requirements also define the performance, in single and three-phase a.c. or d.c. systems having rated voltages up to 1 000 V a.c. or up to 1 500 V d.c. These devices are fixed installed or portable. They are intended to be used indoors and/or outdoors. This standard is not applicable for: - electricity metering equipment that complies with IEC 62053-21, IEC 62053-22 and IEC 62053-23. Nevertheless, uncertainties defined in this standard for active and reactive energy measurement are derived from those defined in the IEC 62053 standards series. - simple remote relays or simple monitoring relays. This standard is intended to be used in conjunction with IEC 61557-1 (unless otherwise specified), which specifies the general requirements for measuring and monitoring equipment, as required in IEC 60364-6. The standard does not include the measurement and monitoring of electrical parameters defined in Parts 2 to 9 of IEC 61557 or in IEC 62020. Combined performance measuring and monitoring devices (PMD), as defined in this standard, give additional safety information, which aids the verification of the installation and enhances the performance of the distribution systems. For instance, those devices help to check if the level of harmonics is still compliant with the wiring systems as required in IEC 60364-5-52. The combined performance measuring and monitoring devices (PMD) for electrical parameters described in this standard are used for general industrial and commercial applications. A PMD-A is a specific PMD complying with requirements of IEC 61000-4-30 class A, which may be used in "power quality assessment" applications.




Standard NumberBS EN 61557-12:2008
TitleElectrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Performance measuring and monitoring devices (PMD)
StatusCurrent, Work in hand
Publication Date30 June 2008
Normative References(Required to achieve compliance to this standard)IEC 62053-22:2003, IEC 62053-21:2003, IEC 62053-31:1998, IEC 60068-2-2:1974, IEC 62053-23:2003, EN 60529:1991, IEC 60364-6, EN 61010, IEC 61000-4-30:2003, EN 61000-4-30:2003, EN 60529:1991/Corrigendum:1993, IEC 60068-2-1, EN 62053-21:2003, IEC 61326-1:2005, IEC 61010-1:2001, IEC 61000-4-5, IEC 61557-1:2007, IEC 61010, IEC 60068-2-30, EN 60068-2-2:2007, EN 61000-4-5:2006, IEC 61000-4-15, EN 61557-1:2007, EN 61000-4-15:1998, EN 60068-2-30:2005, EN 62053-31:1998, EN 61010-1:2001, EN 62053-23:2003, EN 61010-1:2001/Corrigendum:2002, EN 60068-2-1:2007, HD 60364-6:2007, EN 62053-22:2003, EN 61326-1:2006, IEC 60529
Informative References(Provided for Information)IEC 60050-604:1987, IEC 62052-11:2003, IEC 60044-7:1999, 2004/108/EC, IEC 60050-601:1985, IEC 60050-131:2002, EN 61000-4-7:2002, IEC 60050-300:2001, IEC 60044-8:2002, EN 61140:2002, IEC 60050-161:1990, IEC 60044-1:1996, IEC 61010-2-030, EN 60044-7:2000, IEC 61000-4-7:2002, EN 60359:2002, IEC 61140:2001, EN 60071-1:2006, IEC 60359:2001, IEEE 1459-2000, IEC 60364-5-52:2001, EN 60044-2:1999, IEC 60044-2:1997, IEC 60050-551-20, IEC 60071-1:2006, EN 60044-1:1999, EN 60044-8:2002
International RelationshipsIEC 60252-1:2001,EN 61557-12:2008,EN 60252-1:2001,IEC 61557-12:2007
Draft Superseded By05/30143872 DC
DescriptorsLow-voltage equipment, Electrical safety, Electrical measuring instruments, Safety devices, Measuring instruments, Low voltage, Probes, Electrical measurement, Electrical protection equipment, Electric power distribution, Performance testing
ICS17.220.20
29.080.01
29.240.01
Title in FrenchSécurité électrique dans les réseaux de distribution basse tension de 1000 V c.a. et 1500 V c.c. Dispositifs de contrôle, de mesure ou de surveillance de mesures de protection. Dispositifs de mesure et de surveillance des performances (PMD)
Title in GermanElektrische Sicherheit in Niederspannungsnetzen bis AC 1000 V und DC 1500 V. Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen. Kombinierte Geräte zur Messung und Überwachung des Betriebsverhaltens
CommitteePEL/85
ISBN978 0 580 56285 3
PublisherBSI
FormatA4
DeliveryYes
Pages82
File Size1.186 MB
Price£274.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Collaborate, Innovate, Accelerate.