BS EN 15319:2007 - General principles of design of fibrous (gypsum) plaster works

BS EN 15319:2007

General principles of design of fibrous (gypsum) plaster works

Status : Current, Under review   Published : August 2007

Format
PDF

Format
HARDCOPY



This European Standard defines the principles for the design of works carried out using fibrous (gypsum) plaster products as defined in EN 13815. Fibrous (gypsum) plaster casts from the three categories of production below (see Clause 4 of EN 13815:2006) should be involved: a) ”cpp” allowing regulatory marking CE; b) “cppv” allowing regulatory marking CE; c) “ipp” either when CE marking is required; or without CE marking (see Annex D – Note 2 of EN 13815:2006). This European Standard applies to both new constructions and to the refurbishment, restructuring or conversion of existing buildings. The common fields of application of fibrous plaster are as set out in Table 1 below. Table 1 — Common fields of application of fibrous plaster Fields of application Examples Architectural effects ? decorating: cornices, pilasters, columns (see exception vii below); ? on the ceiling: flat or shaped ceilings (included suspended ceilings), coffered ceilings, vaults, domes; ? in a vertical position : flat or shaped surfaces (partitions, linings); ? encasements, casings; ? embellishments for direct or concealed lighting; ? structures to improve acoustical performance (insulation, absorption, diffusion). Technical functions ? shafts and ducts for ventilation, air conditioning, smoke extraction; ? ceiling voids and chambers for pressurization; ? structures to enhance fire safety. NOTE 1 This classification is not exclusive, as the same fibrous plaster work can have several functions. NOTE 2 Table 1 does not mention the use of fibrous plaster externally; as it can only be used under certain conditions (see 4.3.1.2). Fibrous plastering work should be capable of having the usual finishes applied directly to them (e.g. paint, wallpaper) subject to the normal preparatory work applicable for the type of finish.




Standard NumberBS EN 15319:2007
TitleGeneral principles of design of fibrous (gypsum) plaster works
StatusCurrent, Under review
Publication Date31 August 2007
Normative References(Required to achieve compliance to this standard)EN 13815:2006, ISO 6946:1996, ISO 140-3:1995, BS EN 13501-1:2018, EN 20140-9, ISO 717-1:1996, EN 13279-1, EN ISO 6946, ISO 140-9:1985, EN ISO 717-1, EN ISO 354, ISO 354:2003, EN 13501-2, EN ISO 140-3, EN ISO 10456, ISO 10456:1999, EN 13501-1:2018
Informative References(Provided for Information)96/603/EC, EN 12524, EN 14246, 89/106/EEC, prEN 15283, ISO 7892, EN 13963:2005
International RelationshipsEN 15319:2007
Draft Superseded By05/30138009 DC
DescriptorsSurfaces, Ceilings, Prefabricated parts, Painting, Gypsum plaster, Decorative materials, Reinforced materials, Fibres, Partitions, Plastering, Plasterwork, Design, Construction materials, Plasters
ICS91.100.10
Title in FrenchPrincipes généraux de conception des ouvrages en staff
Title in GermanAllgemeine Grundsätze der Planung von Arbeiten aus Formteilen aus faserverstärktem Gips
CommitteeB/544
ISBN978 0 580 55711 8
PublisherBSI
FormatA4
DeliveryYes
Pages50
File Size679 KB
Price£240.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

The faster, easier way to work with standards


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version