BS EN 14015:2004 - Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above – BSI British Standards

BS EN 14015:2004

Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above

Status : Current, Work in hand   Published : February 2005

Format
PDF

Format
HARDCOPY



Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above

Executive summary

Requirements for the design, manufacture and inspection of steel tanks for the storage of liquids at ambient temperature and above.

Abstract

This European Standard specifies the requirements for the materials, design, fabrication, erection, testing and inspection of site built, vertical, cylindrical, flat bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperatures and above, and the technical agreements that need to be reached.

This standard is concerned with the structural integrity of the basic tank structure and does not provide requirements for considering process design, operational issues, safety and firefighting facilities, in-service inspection, maintenance or repair.

This standard applies to closed-top tanks, with and without internal floating covers and open-top tanks, with and without floating roofs. It does not apply to 'lift-type' gas holders. It is also applicable to steel tanks with a maximum design strength of  60 N/mm2. This standard does not apply to tanks where the product is refrigerated to maintain it as a liquid at atmospheric pressure.

This standard applies to storage tanks with the following characteristics:

a) design pressure less than 500 mbar and design internal negative pressure not lower than 20 mbar;

b) design metal temperature not lower than -40 degrees C and not higher than +300 degrees C;

c) maximum design liquid level not higher than the top of the cylindrical shell.

The limits of application of this Standard terminate at the following locations.

- face of the first flange in a bolted flange connection;

- first threaded joint on the pipe or coupling outside of the tank shell, roof or bottom;

- first circumferential joint in a pipe not having a flange connection.

History and related standards

This European Standard supersedes BS 2654:1989 which is withdrawn.

This Standard includes the following cross-references:

EN 287-1:2004, EN 288-2, EN 444, EN 462-1, EN 462-2, EN 473, EN 485 (all parts), EN 499, EN 571-1, EN 754 (all parts), EN 755 (all parts), EN 970, EN 1092-1, EN 1290, EN 1418, EN 1435, EN 1593, EN 1600, EN 1714, prEN 1759-1:2000, EN 1991-1-3:2003, EN 10025:1992, EN 10028-2: 1993, EN 10028-3:1993, EN 10029:1991, EN 10045-1, EN 10088-1, EN 10088-2:1995, EN 10088-3:1995, EN 10113-2:1993, EN 10113-3:1993, EN 10204: 2004, EN 10210-1:1994, EN 10216-1, EN 10216-2, EN 10216-3, EN 10216-5, EN 10217-1, EN 10217-2, EN 10217-3, EN 10217-5, prEN 10217-7, EN 10222 (all parts), EN 10250 (all parts), EN 12874, ENV 1991-2-1, ENV 1993-1-1, ENV 1993-4-2, EN ISO 4063,

EN ISO 6520-1, EN ISO 14122-1, EN ISO 14122-2, EN ISO 14122-3,

EN ISO 14122-4, EN ISO 15607:2003 and EN ISO 15614-1:2004.




Standard NumberBS EN 14015:2004
TitleSpecification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above
StatusCurrent, Work in hand
Publication Date04 February 2005
Normative References(Required to achieve compliance to this standard)ISO 14122-3:2001, ISO 15614-1:2004, EN 462-2, EN 755, ISO 14122-1:2001, EN ISO 15607:2003, prEN 10217-7, EN 10216-5, EN 10088-3:1995, EN 10028-2:1993, EN ISO 15614-1:2004, EN 1435, ENV 1991-2-1, EN 10216-2, EN 10025:1992, prEN 1759-1:2000, EN ISO 6520-1, EN 499, EN 10025, EN 473, ISO 14122-2:2001, ISO 14122-4:1996, EN 571-1, EN 10088-1, EN 10216-1, ENV 1993-4-2, EN ISO 14122-3, EN 462-1, EN 12874, EN ISO 14122-2, EN 10028-3:1993, EN 10045-1, EN 444, EN 10113-3:1993, EN 287-1:2004, EN 1092-1:2018, EN 10204:2004, EN 10113-2:1993, EN 1991-1-3:2003, ISO 4063:1998, ISO 6520-1:1998, EN 10029:1991, EN 1593, ENV 1993-1-1, EN 1714, EN 10002-5, EN 10217-5, EN ISO 4063, EN 970, EN 10216-3, EN 10088, EN 10217-3, EN 10088-2:1995, EN 288-2, EN ISO 14122-4, EN ISO 14122-1, EN 485, EN 10222, EN 10250, EN 10217-1, EN 10210-1:1994, EN 1600, EN 1418, EN 10217-2, ISO 15607:2003, EN 754, EN 1290
Informative References(Provided for Information)EN 10279, EN 573-3:2003, EN 10164, EN 10056-1, EN 10326, ENV 1998-1-1, 94/63/EC, EN 13445, EN 13480, EN 10163, API 653, prEN 14620, NFPA 30
ReplacesBS 2654:1989
International RelationshipsEN 14015:2004
Amended ByAMD 15597
Corrigendum, February 2005
DescriptorsStructural design, Welded joints, Vertical, Test methods, Steels, Design, High temperatures, Liquids, Inspection, Lids, Conformity, Ambient temperature, Covers, Tanks (containers), Production, Bottom, Cylindrical shape, Storage, Bulk storage containers, In situ, Flat (shape)
ICS23.020.10
75.200
Title in FrenchSpecification pour la conception et la fabrication de reservoirs en acier, soudes, aeriens, a fond plat, cylindriques, verticaux, construit sur site destines au stockage des liquides a la temperature ambiante ou superieure
Title in GermanAuslegung und Herstellung standortgefertigter, oberirdischer, stehender, zylindrischer, geschweisster Flachboden-Stahltanks fuer die Lagerung von Fluessigkeiten bei Umgebungstemperatur und hoeheren Temperaturen
CommitteePVE/15
ISBN0 580 45461 4
PublisherBSI
FormatA4
DeliveryYes
Pages250
File Size1.868 MB
Price£392.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Collaborate, Innovate, Accelerate.


Worldwide Standards
We can source any standard from anywhere in the world


Customers who bought this product also bought

  • BS EN 12285-2:2005
    Workshop fabricated steel tanks Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids
  • BS 1377-7:1990
    Methods of test for soils for civil engineering purposes Shear strength tests (total stress)
  • BS 1377-6:1990
    Methods of test for soils for civil engineering purposes Consolidation and permeability tests in hydraulic cells and with pore pressure measurement
  • BS 1377-4:1990
    Methods of test for soils for civil engineering purposes Compaction-related tests