BS EN 61779-1:2000 - Electrical apparatus for the detection and measurement of flammable gases. General requirements and test methods
Maintenance will be taking place for BSI Shop on Saturday 18th January between 08:00 and 14:00 PM UK time. BSI Shop will be unavailable during this time or will have limited functionality. Please accept our apologies for any inconvenience caused during this essential maintenance.

Find Similar Items

This product falls into the following categories.

You may find similar items within these categories by selecting from the choices below:

BS EN 61779-1:2000

Electrical apparatus for the detection and measurement of flammable gases. General requirements and test methods

Status : Superseded, Withdrawn   Published : September 2000 Replaced By : BS EN 60079-29-1:2007

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


Applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, for example houses, apartments; - retail outlets, for example shops, supermarkets; - business premises, for example offices, banks; - areas of public entertainment, for example cinemas, public bars, dance halls; - outdoor locations, for example petrol stations, car parks, amusement and sports centres; - light-industrial locations, for example workshops, laboratories, service centres. Locations which are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at residential, commercial and light-industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements. Test requirements are specified for each port considered.




Standard NumberBS EN 61779-1:2000
TitleElectrical apparatus for the detection and measurement of flammable gases. General requirements and test methods
StatusSuperseded, Withdrawn
Publication Date15 September 2000
Withdrawn Date01 November 2010
Cross ReferencesEN 61000-4-4:1995, ISO 6142:1981, IEC 60079-10:1986, ISO 6147:1979, IEC 60079-5:1967, IEC 60079-2:1983, EN 61000-4-1:1994, IEC 60079-0:1983, IEC 60050-351:1975, IEC 60079-6:1995, ISO 6145-3:1986, EN 50270:1999, IEC 60079-18:1992, IEC 61000-4-4:1995, IEC 60079-1:1990, ISO 6145-4:1986, IEC 60079-13:1982, IEC 60079-7:1990, IEC 61000-4-1:1992, IEC 60079-15:1987, ISO 6145-1:1986, IEC 60079-19:1993, EN 50073:1999, ISO 6145-6:1986, IEC 60079-11:1991, prEN 50271, EN 61000-4-3:1996, IEC 60079-14:1984, IEC 61000-4-3:1995
Replaced ByBS EN 60079-29-1:2007
ReplacesBS EN 50054:1999
International RelationshipsIEC 61000-6-1:2005,EN 61779-1:2000
Amended ByAMD 15396
Amendment, October 2004
Draft Superseded By99/242136 DC
DescriptorsGas detectors, Electrical testing, Hazards, Flammable atmospheres, Flammable materials, Electronic equipment and components, Electrical equipment, Protected electrical equipment, Detectors, Fire risks, Gases, Safety devices, Warning devices
ICS13.320
29.260.20
33.100.20
75.180.30
Title in FrenchAppareils electriques de detection et de mesure des gaz combustibles. Regles generales et methodes d'essai
Title in GermanElektrische Geraete fuer die Detektion und Messung brennbarer Gase. Allgemeine Anforderungen und Pruefverfahren
CommitteeEXL/31
ISBN0 580 36426 7
PublisherBSI
FormatA4
DeliveryNo
Pages60
File Size896 KB
Price£254.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Collaborate, Innovate, Accelerate.


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Customers who bought this product also bought

  • BS 5588-9:1999
    Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork
  • BS 5306-1:2006
    Code of practice for fire extinguishing installations and equipment on premises Hose reels and foam inlets
  • BS 7899-2:1999
    Code of practice for assessment of hazard to life and health from fire Guidance on methods for the quantification of hazards to life and health and estimation of time to incapacitation and death in fires
  • BS 5588-0:1996
    Fire precautions in the design, construction and use of buildings Guide to fire safety codes of practice for particular premises/applications