BS EN 50200:2006 - Method of test for resistance to fire of unprotected small cables for use in emergency circuits

BS EN 50200:2006

Method of test for resistance to fire of unprotected small cables for use in emergency circuits

Status : Revised, Superseded, Withdrawn   Published : June 2006 Replaced By : BS EN 50200:2015

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001


This European Standard specifies the test method for cables designed to have intrinsic resistance to fire and intended for use as emergency circuits for alarm, lighting and communication purposes. This standard is applicable to cables, for emergency circuits, of rated voltage not exceeding 600/1 000 V, including those of rated voltage below 80 V, and for emergency circuit optical cables. NOTE Although test procedures for electronic data and communication cables and optical fibre cables are given in this document, these areas are under active development and the given procedures may be subject to future review. This standard is not applicable to cables intended for use in public telecommunications networks. The test method is limited to cables with an overall diameter not exceeding 20 mm. The test method, which is based on the direct impingement of flame from a propane burner giving a constant temperature attack of a notional 842 °C, can be used for cables for emergency circuits required to comply with Subclause 4.3.1.4.6 (a) of the Interpretative Document for Essential Requirement No. 2 'Safety in Case of Fire' (94/C62/01) of the Construction Products Directive (89/106/EEC). In such cases the test method only applies, for metallic conductor cables, to those with conductor sizes up to and including 2,5 mm2. For optical cables, only the 20 mm diameter limit applies. This standard includes (Annex D) a means of linking the measured survival time to the fire resistance classification for these cables, as required by Subclause 4.3.1.4.6(a) of 94/C62/01. The standard also includes (Annex E) a means of applying a water spray to the cable during the test. Although there is no requirement under the Construction Products Directive for cables to withstand water spray when assessing resistance to fire, such a requirement may be a feature of particular product standards.




Standard NumberBS EN 50200:2006
TitleMethod of test for resistance to fire of unprotected small cables for use in emergency circuits
StatusRevised, Superseded, Withdrawn
Publication Date30 June 2006
Withdrawn Date31 December 2015
Normative References(Required to achieve compliance to this standard)HD 60269-3-1, EN 60695-4, IEC 60695-4, IEC 60584-1, IEC 60269-3-1:2004, EN 60584-1, IEC 60793-1-4:1995
Informative References(Provided for Information)IEC 61034-1, EN 61034-1, EN 1363-1
Replaced ByBS EN 50200:2015
ReplacesBS EN 50200:2000, BS 8434-1:2003
International RelationshipsIEC 61223-3-5:2004/COR1:2006,EN 50200:2006
Draft Superseded By03/310352 DC
DescriptorsLighting systems, Data transmission, Emergency lighting, Fire tests, Electric conductors, Fibre optic cables, Circuits, Alarm systems, Electric cables, Communication cables, Fire-resistant materials, Fire resistance, Rated voltage
ICS13.220.40
29.060.20
Title in FrenchMethode d'essai de resistance au feu des cables de petites dimensions sans protection pour utilisation dans les circuits de secours
Title in GermanPruefung des Isolationserhaltes im Brandfall von Kabeln mit kleinen Durchmessern fuer die Verwendung Notstromkreisen bei ungeschuetzter Verlegung
CommitteeGEL/20/18
ISBN0 580 48751 2
PublisherBSI
FormatA4
DeliveryNo
Pages32
File Size676 KB
Price£182.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
Customer Relations
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Customers who bought this product also bought

  • BS 8434-2:2003+A2:2009
    Methods of test for assessment of the fire integrity of electric cables Test for unprotected small cables for use in emergency circuits. BS EN 50200 with a 930° flame and with water spray
  • BS EN 50362:2003
    Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
  • BS 6387:2013