Installation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases) – Specification

Executive summary

Specification for the installation and maintenance of direct gas-fired tumble dryers of up to 6 kW net heat input.

Abstract

This British Standard specifies the installation, including design, inspection and commissioning, of direct gas-fired tumble dryers of up to 6 kW net heat input burning 2nd and 3rd family gases for use in permanent domestic dwellings. It applies to any such tumble dryer used in conjunction with a flexible venting hose fitted to a wall or window vent terminal or, where the net heat input does not exceed 3kW, with a venting hose hung out of a window, so that combustion products and moisture are exhausted directly to the outside air.

This revision to BS 7624 reflects changes to the relevant legislation and the publication of BS EN 1458-1:2000, which covers the safety of gas fired tumble dryers and replaces BS 5258-17. The previously accepted use of a tumble dryer in a flueless mode is not recognized in BS EN 1458 and, accordingly, this standard only endorses the venting options detailed in the scope.

History and related standards

This British Standard supersedes BS 7624:1993, which is withdrawn.

This standard includes the following cross references:

BS 669-1, BS 5440-2:2000, BS 5482-1, BS 6891, BS 7671.

This British Standard specifies the installation (see Note 1) of direct gas-fired tumble dryers of up to 6 kW net heat input burning 2nd and 3rd family gases for use in permanent domestic dwellings (see Notes 2 and 3).

It applies to any such tumble dryer used in conjunction with a flexible venting hose fitted to a wall or window vent terminal or, where the net heat input does not exceed 3kW, with a venting hose hung out of a window, so that combustion products and moisture are exhausted directly to the outside air.

NOTE 1 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognized that each of these tasks can be performed by the same person.

NOTE 2 As well as normally constructed dwellings, domestic premises include any permanently sited caravans, holiday homes, residential park homes and permanently moored boats. Additional requirements exist for these categories of premises and can be found in IGE/UP/8 [8]. Neither this standard nor IGE/UP/8 [8] applies to gas installations in towed or motorised caravans.

NOTE 3 Whilst this standard specifies installations in domestic premises, it is recognized that it might also be referred to for similar installations in commercial and industrial premises. In such cases, additional legislation might be applicable. Attention is drawn to the hazards that exist in certain locations, e.g. hairdressing salons, where the atmosphere or drying load can contain flammable vapours.

ISBN 0 580 44184 9




Standard NumberBS 7624:2004
TitleInstallation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases). Specification
StatusConfirmed, Current
Publication Date17 August 2004
Confirm Date01 June 2016
Normative References(Required to achieve compliance to this standard)BS 669-1, BS 5440-2:2000, BS 5482-1, BS 6891, BS 7671
Informative References(Provided for Information)BS 5440-1:2000, BS 5258-17:1992, BS EN 778:1998, BS EN 1319:1999, BS EN 1458-1:2000, DD 221:1997, Gas Safety (Installation and Use) Regulations 1998, Gas Safety (Installation and Use) Regulations, (Northern Ireland) 2004, Gas Appliances (Safety) Regulations 1995, Building Regulations 2000, Building Standards (Scotland) Regulations 1990, Building Regulations (Northern Ireland) 2000, Gas Safety (Application) (Isle of Man) Order 1996
ReplacesBS 7624:1993
Draft Superseded By01/707909 DC
DescriptorsTumble driers, Gas-powered devices, Laundry equipment, Cleaning equipment, Household equipment, Domestic, 2nd family gases, 3rd family gases, Heat capacity, Installation, Maintenance, Ventilation, Ventilation equipment
ICS27.060.20
97.060
Title in FrenchSpecification de l'installation d'essoreuses domestiques au gaz dont la puissance calorifique est inferieure ou egale a 3 kW (gaz des familles secondaire et tertiaire)
Title in GermanSpezifikation fuer den Einbau von direkt mit Gas beheizten Waeschetrocknern fuer den Haushalt mit einer Waermeeingangsleistung bis zu 3 kW (2. und 3. Haushaltgase)
CommitteeGSE/30/-/20
ISBN0 580 44184 9
PublisherBSI
FormatA4
DeliveryYes
Pages18
File Size540.5 KB
Price£130.00


 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Worldwide Standards
We can source any standard from anywhere in the world


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought

  • BS 5871-1:2005
    Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Gas fires, convector heaters, fire/back boilers and heating stoves (2nd and 3rd family gases)
  • BS 5871-3:2005
    Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Decorative fuel effect gas appliances of heat input not exceeding 20 kW (2nd and 3rd family gases)
  • BS 5871-4:2007
    Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input not exceeding 6 kW (2nd and 3rd family gases)
  • BS 7967-4:2007
    Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances