Electrical apparatus for explosive gas atmospheres - Part 15 Type of protection “n”

Long abstract

This European Standard specifies requirements for the construction, testing and marking for Group II electrical apparatus with type of protection “n”, intended for use only in areas where explosive atmospheres of gas, vapour and mist are unlikely to occur or if they do occur, are likely to do so infrequently or for a short period only.

This standard is applicable to non-sparking electrical apparatus and also to apparatus with parts or circuits producing arcs or sparks or having hot surfaces which, if not protected in one of the ways specified in this standard, could be capable of igniting a surrounding explosive atmosphere.

This standard is also applicable to electrical equipment and components of Group II, Category 3G.

Short abstract

Requirements for construction, testing and marking of electrical apparatus with type of protection “n”.

History and related standards

This European Standard supersedes BS EN 50021:1999 which is withdrawn. It also partially supersedes DD ENV 50269:1997 which is also withdrawn.

This standard includes the following cross references:

IEC 60034 (all parts), IEC 60034-1:1996, IEC 60034-5, IEC 60050-411, IEC 60050(426), IEC 60050(486), IEC 60060 (all parts), IEC 60061 (all parts), IEC 60068-2-27:1987, IEC 60079-0:1998, IEC 60079-2, IEC 60079-11, IEC 60081, IEC 60112, IEC 60155, IEC 60216-1:1990, IEC 60216-2, IEC 60238:1998, IEC 60269-3, IEC 60400, IEC 60529:1989, IEC 60598-1:1996, IEC 60598-2 (all parts), IEC 60662:1992, IEC 60664-1, IEC 60920, IEC 60922, IEC 60924, IEC 60926: 1995, IEC 60927, 1996, IEC 60928: 1995, IEC 60998-2-4: 1991, IEC 61048, IEC 61049, IEC 61184.


BS EN 60079-14:2003 provides specifications to reduce the likelihood of explosion from electrical apparatus installed in areas where dangerous concentrations and quantities of flammable gases, vapours, mists, ignitable fibres or dusts that may be present in the atmosphere.

Contents include information on:

selection of electrical apparatus
additional requirements for the installation of:
- type of protection ‘d’ flameproof enclosures
- type of protection ‘e’ increased safety
- type of protection ‘i’ intrinsic safety
- type of protection ‘p’ pressurized apparatus
additional requirements for apparatus suitable only for use in zone 2.




Standard NumberBS EN 60079-14:2003
TitleElectrical apparatus for explosive gas atmospheres. Electrical installations in hazardous areas (other than mines)
StatusRevised, Withdrawn
Publication Date10 September 2003
Withdrawn Date31 January 2009
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Replaced ByBS EN 60079-14:2008
ReplacesBS EN 60079-14:1997, IEC 60079-14:1996
International RelationshipsEN 60079-14:2003,IEC 60079-14:2002
Draft Superseded By00/241830 DC
DescriptorsExplosive atmospheres, Electrical equipment, Protected electrical equipment, Electrical safety, Hazardous areas classification (for electrical equipment), Electrical installations, Design, Zone 0 hazardous areas, Zone 1 hazardous areas, Zone 2 hazardous areas, Classification systems, Temperature, Electric wiring systems, Electric cables, Electric conduits, Circuits, Overload protection, Earthing, Marking, Type p protected electrical equipment, Rated voltage, Type d protected electrical equipment, Type e protected electrical equipment, Verification
ICS13.230
29.260.20
Title in FrenchMateriel electrique pour atmospheres explosives gazeuses. Installations electriques dans les emplacements dangereux (autres que les mines)
Title in GermanElektrische Betriebsmittel fuer gasexplosionsgefaehrdete Bereiche. Errichtung elektrischer Anlagen in explosionsgefaehrdeten Bereichen (ausgenommen Grubenbaue)
CommitteeEXL/31/3
ISBN0 580 42598 3
PublisherBSI
FormatA4
DeliveryNo
Pages66
File Size1.104 MB
Price£254.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


BSOL

The faster, easier way to work with standards


Collaborate, Innovate, Accelerate.


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Customers who bought this product also bought

  • BS EN 60079-0:2006
    Electrical apparatus for explosive gas atmospheres General requirements
  • BS EN 60079-11:2007
    Explosive atmospheres Equipment protection by intrinsic safety "i"
  • BS EN 60079-18:2004
    Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection encapsulation "m" electrical apparatus
  • BS EN 60079-2:2007
    Explosive atmospheres Equipment protection by pressurized enclosure "p"