BS EN 62271-200:2004 - High-voltage switchgear and controlgear. AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

BS EN 62271-200:2004

High-voltage switchgear and controlgear. AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

Status : Superseded, Withdrawn   Published : October 2005 Replaced By : BS EN 62271-202:2014, BS EN 62271-200:2012

WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001


Specifies requirements for factory-assembled metal-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. This standard defines several types of metal enclosed switchgear and controlgear which differ due to - the consequences on network service continuity in case of maintenance on the switchgear and controlgear; - the need and convenience of maintenance of the equipment. For metal-enclosed switchgear and controlgear containing gas-filled compartments, the design pressure is limited to a maximum of 300 kPa (relative pressure). Metal-enclosed switchgear and controlgear for special use, for example, in flammable atmospheres, in mines or on board ships, may be subject to additional requirements. Components contained in metal-enclosed switchgear and controlgear are to be designed and tested in accordance with their various relevant standards. This standard supplements the standards for the individual components regarding their installation in switchgear and controlgear assemblies. This standard does not preclude that other equipment may be included in the same enclosure. In such a case, any possible influence of that equipment on the switchgear and controlgear is to be taken into account. This first edition of IEC 62271-200 cancels and replaces the third edition of IEC 60298, published in 1990, and constitutes a technical revision. Significant technical changes from the third edition of IEC 60298 are as follows: This revised document has been basically changed to be updated to today's use of high- voltage switchgear and controlgear up to 52 kV. The main changes are: new definitions and classification of equipment, introduction of internal arc classes (IAC) and its testing. This standard is to be read in conjunction with IEC 60694 published in 1996. Clause numbering follows the clause numbering of that standard. Additional subclauses, as they relate to a particular clause or subclause from IEC 60694, are numbered 101, 102, etc.




Standard NumberBS EN 62271-200:2004
TitleHigh-voltage switchgear and controlgear. AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
StatusSuperseded, Withdrawn
Publication Date31 October 2005
Withdrawn Date30 November 2014
Normative References(Required to achieve compliance to this standard)EN 60270:2001, IEC 60932:1988, IEC 60050-441:1984, EN 60529:1991, IEC 60270:2000, IEC 60060-1:1989, EN 60909-0:2001, IEC 60466:1987, IEC 61634:1995, IEC 60243-1:1998, IEC 62271-102:2001, IEC 60480:1974, EN 60265-1:1998, EN 60694:1996, IEC 60529:1989, EN 60694:1996/Corrigendum:1999, EN 62271-100:2001, EN 60529:1991/Corrigendum:1993, IEC 60909-0:2001, IEC 60470:2000, IEC 62271-100:2001, IEC 60050-151:2001, EN 60243-1:1998, CENELEC HD 588.1 S1:1991, IEC 60265-1:1998, ISO/IEC Guide 51:1999, EN 62271-105:2003, EN 62271-102:2002, IEC 62271-105:2002, IEC 60694:1996
Informative References(Provided for Information)IEC 60517:1990, IEC 60137:1995, EN 50187:1996, IEC 60724:2000, IEEE C 37.20.7:2001
Replaced ByBS EN 62271-202:2014, BS EN 62271-200:2012
ReplacesBS EN 60298:1996, IEC 60298:1990
International RelationshipsEN 62271-200:2004,IEC 61193-3:2013,IEC 62271-200:2003
DescriptorsAlternating current, Dielectric measurement, Rated frequencies, Artificial weathering tests, Mechanical testing, Metals, Earthing, Leak tests, Control equipment, Switchgear, Electrical equipment, Electrical protection equipment, Testing conditions, Performance testing, Rated voltage, Partial discharges, Electric enclosures, Temperature-rise limit, Electrical testing, Type testing, Fault currents, Electric control equipment, High-voltage equipment, Design
ICS29.130.10
31.190
Title in FrenchAppareillage a haute tension. Appareillage sous enveloppe metallique pour courant alternatif de tensions assignees superieures a 1 kV et inferieures ou egales a 52 kV
Title in GermanHochspannungs-Schaltgeraete und -Schaltanlagen. Metallgekapselte Wechselstrom-Schaltanlagen fuer Bemessungsspannungen ueber 1 kV bis einschliesslich 52 kV
CommitteePEL/17
ISBN0 580 46169 6
PublisherBSI
FormatA4
DeliveryNo
Pages92
File Size1.577 MB
Price£274.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


Worldwide Standards
We can source any standard from anywhere in the world


Collaborate, Innovate, Accelerate.


Customers who bought this product also bought