This Published Document provides guidance on evaluating fire growth and/or size within the enclosure of fire origin, as well as enclosures to which the fire has subsequently spread. Guidance is also provided for “special cases” which include malicious fires, racked/stacked storage of goods and fires external to the
building.

The characteristics of the design fire for any particular scenario are influenced by a number of factors, including building design, environmental influences, potential ignition sources and location, types of combustible materials, distribution and arrangement of combustible materials, ventilation conditions and other events occurring during the fire.

The determination of the characteristics of the design fire from ignition through to decay is used by other Sub-systems as inputs into calculations of events such as time of fire spread from enclosure [PD 7974-3 (Sub-system 3)] and time to activation of suppression systems [PD 7974-4 (Sub-system 4)].




Standard NumberPD 7974-1:2003
TitleApplication of fire safety engineering principles to the design of buildings. Initiation and development of fire within the enclosure of origin (Sub-system 1)
StatusSuperseded, Withdrawn
Publication Date31 March 2003
Confirm Date01 June 2016
Withdrawn Date27 March 2019
Normative References(Required to achieve compliance to this standard)No other standards are normatively referenced
Informative References(Provided for Information)No other standards are informatively referenced
Replaced ByPD 7974-1:2019
DescriptorsSafety engineering, Buildings, Hazard prevention in buildings, Structural fire protection, Fire stops, Fire safety, Enclosures, Fire spread prevention, Means of escape from fire in buildings, Design, Fire safety in buildings, Ignitability
ICS13.220.20
91.040.01
CommitteeFSH/24
ISBN0 580 41195 8
PublisherBSI
FormatA4
DeliveryYes
Pages76
File Size931 KB
Price£274.00


WITHDRAWN TITLE
*To ask about withdrawn titles contact the
BSI Customer Services
cservices@bsigroup.com, +44 345 086 9001
 Your basket
Your basket is empty

Multi-user access to over 3,500 medical device standards, regulations, expert commentaries and other documents


Develop a PAS

Develop a fast-track standardization document in 9-12 months


Tracked Changes

Understand the changes made to a standard with our new Tracked Changes version


BSOL

The faster, easier way to work with standards


Customers who bought this product also bought

  • PD 7974-0:2002
    Application of fire safety engineering principles to the design of buildings Guide to design framework and fire safety engineering procedures
  • PD 7974-4:2003
    Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)
  • BS 7974:2001
    Application of fire safety engineering principles to the design of buildings. Code of practice
  • PD 7974-5:2014
    Application of fire safety engineering principles to the design of buildings Fire and rescue service intervention (Sub-system 5)